Warning
To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of:
158°F (60°C) Statement 1047
Warning
Installation of the equipment must comply with local and national electric codes. Statement 1074
Explosion Hazard—The area must be known to be nonhazardous before installing, servicing, or
Warning
replacing the unit. Statement 1082
Use twisted-pair supply wires suitable for 86°F (30°C) above surrounding ambient temperature
Warning
outside the enclosure. Statement 1067
Avoid using or servicing any equipment that has outdoor connections during an electrical storm.
Warning
There may be a risk of electric shock from lightning. Statement 1088
Caution
Airflow around the device must be unrestricted. To prevent the device from overheating, ensure these
minimum clearances:
– Top and bottom: 1.0 inches (25 mm)
– Exposed side (not connected to the module): 1.0 inches (25 mm)
– Front: 1.0 inches (25 mm)
Contact your Cisco Technical Assistance Centre (TAC) if tighter spacings are required.
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D, or only nonhazardous
Caution
locations.
Caution
The equipment shall only be used in an area of not more than pollution degree 2 as defined by EN
60664-1. In addition, the equipment shall be installed in an ATEX certified enclosure that provides a
degree of protection not less than IP 54 in accordance with EN 60079-15.
This equipment is rated as follows:
Note
- DC Input Voltage: Maximum Operating Range: 9.6VDC to 60VDC; Nominal: 12VDC to 48VDC
The maximum ambient operating temperature range is –40 to 140°F (–40 to 60°C).
Note
Product Documentation and Compliance Information for the Cisco ISA 3000 Industrial Security Appliance