Normal dynamic signals will not cause the amplifier to overheat unless the ventilation is
inadequate. (See installation section and maintenance section.)
Fault Indicator (Audio Protection – red LED)
If the outputs are shorted or if DC is present, the protection circuit will disengage the outputs and the
A/P LED will illuminate. The amplifier will continue to be monitored and depending on the type of fault,
will either reset after the fault has cleared or require manual resetting by switching off at the mains
switch and then on again after a few seconds. (See also temperature control above).
Temperature related faults will reset once the unit has cooled sufficiently.
Output short circuits will require manual reset after clearing the fault. Short circuits on either channel
will affect the individual channel. A/P will illuminate together with the Limit LED on the shorted channel.
CH Link LED (amber)
These indicate the position of the input link switches on the rear panel and are illuminated when
relevant CH Link mode is selected with the switch pressed in.