Blower; Snap Disc - Hearth and Home Technologies VERMONT CASTINGS MONTP-II-CB Owner's Manual

Table of Contents

Advertisement

C. Blower
Service Part: SRV7000-868
1. Ensure that the fire is out and the appliance is cool to
the touch.
2. The grille on the blower access assembly is hinged.
Swing the grille downward to expose the 2 screws
(Figure 23.1).
3. Remove the 2 screws from the blower access assembly
and slide assembly away from the appliance.
4. Disconnect the wires from the blower.
5. Remove the 2 screws from the hold down bracket and
pull the blower and bracket forward.
6. Remove the blower from the hold down bracket.
7. Re-install in reverse order. Be certain that the hold down
bracket's screws are completely seated in the grommets.
Insert the locating tab in the hold down bracket into the
placement slot.
CAUTION!
Shock Risk.
Do NOT remove grounding prong
from plug.
Plug directly into properly grounded 3
prong receptacle.
Route cord away from appliance.
Do NOT route cord under or in front
of appliance.
Figure 23.1
October 23, 2019
D. Snap Disc
Service Part: SRV230-0470
1. Ensure that the fire is out and the appliance is cool to
the touch.
2. The grille on the blower access assembly is hinged.
Swing the grille downward to expose the 2 screws
(Figure 23.1).
3. Remove the 2 screws from the blower access
assembly and slide assembly away from the appliance
4. Remove the 2 mounting screws on the blower
assembly and slide assembly towards you.
5. Using a Phillips head screw driver, remove the 2
screws from the snap disc and lift the snap disc off
of the mounting bracket. Disconnect the wires and
replace with new snap disc and re-connect the wires.
6. Slide the blower assembly back into position and
secure with the 2 mounting screws.
Figure 23.2
7101-803E
MONTPELIER II INSERT
23

Advertisement

Table of Contents
loading

Table of Contents