G1528
STEAKHOUSE PLUS GRILL
INSTALLATION and
SERVICING INSTRUCTIONS
These appliances must be installed and serviced by a competent person as stipulated
by the Gas Safety (Installation & Use) Regulations.
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these
instructions and National Regulations in force at the time of installation. Particular attention
MUST be paid to –
Gas Safety (Installation & Use) Regulations Health and Safety at Work, etc. Act
Local and National Building Regulations
Detailed recommendations are contained in the Institute of Gas Engineers published
documents: IGE/UP/1, IGE/UP/2 BS6173 and BS5440
These appliances have been CE-marked on the basis of compliance with the Gas Appliance
Directive for the Countries, Gas Types and Pressures as stated on the Data Plate.
WARNING - TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR
ELECTRIC, MUST BE EARTHED
On completion of the installation, these instructions should be left with the Engineer-in-
Charge for reference during servicing. Further to this, the Users Instructions should be
handed over to the User, having had a demonstration of the operation and cleaning of the
appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE
INSTALLING AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH
THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A
SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a
Maintenance Contract be arranged with SERVICELINE. Visits may then be made at agreed
intervals to carry out adjustments and repairs. A quotation will be given upon request to the
contact numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO
At end of unit life, dispose of appliance and any replacement parts in a safe
manner, via a licensed waste handler.
Units are designed to be dismantled easily and recycling of all material is
encouraged whenever practicable.
Falcon Foodservice Equipment
Head Office and Works
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
Serviceline PHONE: 01438 363 000
Fire Precautions Act
T100702 Ref.4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G1528 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Falcon G1528

  • Page 1 At end of unit life, dispose of appliance and any replacement parts in a safe manner, via a licensed waste handler. Units are designed to be dismantled easily and recycling of all material is encouraged whenever practicable. Falcon Foodservice Equipment Head Office and Works Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland. T100702 Ref.4...
  • Page 2 Warranty Policy Shortlist Warranty does not cover :- Correcting faults caused by incorrect installation of a product. Where an engineer cannot gain access to a site or a product. Repeat commission visits. Replacement of any parts where damage has been caused by misuse. Engineer waiting time will be chargeable.
  • Page 3: Section 1 - Installation

    DEPTH HEIGHT WEIGHT MODEL G1528 1.2 SITING Each unit must be installed level in a well-lit and draught-free position. A minimum vertical clearance of 550mm in still air is required above the grill flue top edge to ensure no overheating of overlying surfaces.
  • Page 4 1.6 WATER SUPPLY Not applicable on this appliance. 1.7 TOTAL RATED HEAT INPUT Natural (I Propane (I Control Kw(nett) Btu/hr (gross) Kw(nett) Btu/hr (gross) position G1528 Full 13.1 49,000 13.1 49,000 G1528 18,400 18,400 Turndown / low. Per burner pair.
  • Page 5: Section 2 - Assembly And Commissioning

    This device MUST NOT be fitted on PROPANE models. 1.10 BURNER ADJUSTMENTS 1.10.1 To Adjust a) Fit a suitable pressure gauge to test point and light grill. Consult Users Instructions for lighting procedure. b) With one burner (pair) at FULL FLAME position, adjust pressure if necessary. Values are stated in Section 1.9.
  • Page 6 Figure 1...
  • Page 7: Parts List

    2.1.3 Floor Stand Assembly Instructions PARTS LIST Description No. off LH Support (A) Shelf (B) RH Support (C) Front Skirt (D) Adjustable Feet M5 x 10 Screws M6 x 12 Screws M5 Shakeproof Washers M6 Shakeproof Washers a) Fix both shelves (B) to end supports (A & C) using M5 screws provided. b) Fix front skirt (D) to end supports (A &C) using M5 screws provided.
  • Page 8 2.1.4 Wall Bracket Important The wall must be capable of supporting a fully assembled grill under normal conditions of use. Fixing must be made in such a way as to achieve a rigid support. Fixing arrangements should follow sound building practices. Figure 3 Hold bracket against wall in desired position.
  • Page 9: Section 3 - Servicing And Commissioning

    2.1.5 Installing the Appliance. Having selected appliance position and type of mounting, extend gas supply and prepare a suitable gas position connection point. Ensure that a gas isolating cock is fitted in supply at a convenient and accessible position adjacent to grill. On NATURAL gas appliances, fit governor supplied to inlet connection and make final connection to unit.
  • Page 10: Gas Conversion Check List

    3.1 GAS CONVERSION CHECK LIST To convert from NATURAL to PROPANE gas - Change main and x lighter injectors. Adjust low flame setting. Remove governor, adjust inlet pressure accordingly. Change data plate. To convert from PROPANE to NATURAL gas - Change main and x lighter injectors.
  • Page 11 These can be found directly behind rear panel. Note These values refer to a condition with only one burner (pair) lit in LOW position. MODEL Natural Propane G1528 7 mbar 20 mbar Refer to Section 1.9 for full flow pressure. Low flame Setting Screw...
  • Page 12: Section 4 - Spares

    3.7 GOVERNOR This applies to NATURAL GAS appliances only. The type of governor used is maintenance free. Check that blue dust cap for vent is fitted and in good condition. This protects the breather hole. Always re-check pressure at test point following governor maintenance. SECTION 4 - SPARES When ordering spares, always quote appliance type and serial number.

Table of Contents