Bentel Security KYO Series Programming Manual

Bentel Security KYO Series Programming Manual

Programming from keypad
Hide thumbs Also See for KYO Series:

Advertisement

PROGRAMMING FROM KEYPAD
MADE
IN
OHSAS 18001
OHSAS 18001
ISO 14001
ISO 14001
ISO 9001
ISO 9001
9192.BSEC
IT - 60983
9191.BNT2
IT-52588
9105.BNT1
IT-52587
ITALY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KYO Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bentel Security KYO Series

  • Page 1 PROGRAMMING FROM KEYPAD MADE OHSAS 18001 OHSAS 18001 ISO 14001 ISO 14001 ISO 9001 ISO 9001 9192.BSEC IT - 60983 9191.BNT2 IT-52588 9105.BNT1 IT-52587 ITALY...
  • Page 2 R e lease N u m b er ISTPTB LE U NK YO 1 90 5 03 P7 0 C o de D a te BENTEL SECURITY S.r.l. reserves the right to modify the technical specifications of this product without prior notice.
  • Page 3: Table Of Contents

    ® ® ABLE OF ONTENTS Introduction ..............5 Code Limitations ................5 Accepted Keypads ................6 Enrolling an LCD Keypad at Address 08 ......... 6 Adjusting Brightness, Contrast and Volume ........6 The Liquid Crystal Display (LCD) ............ 8 Programming from the LCD Keypad ......9 Customizing the System ..............
  • Page 4 ® ® Multifunction Control Panel Programming from the LED Keypad ......29 Accessing Programming ..............29 Exiting Programming ..............29 Programming ..................30 Keypads ..................30 Readers ..................31 Setting up the Zones ..............32 Setting up the Outputs ..............35 Setting up Times, Inactivity and Negligence ........
  • Page 5: Introduction

    ® ® Introduction NTRODUCTION You can program the system using the ‘KyoUnit’ Software Application and a compu- ter (refer to the “INSTALLATION MANUAL”). You can also program some models from the KYO range via an LED Keypad (refer to the following Table).
  • Page 6: Accepted Keypads

    ® ® Multifunction Control Panel Accepted Keypads You can program the system from LCD Keypads or, for KYO4-8 ONLY, from LED Keypads (Classika and Premium LED). Enrolling an LCD Keypad at Address 08 To enrol an LCD Keypad at Address 08 from a LED Keypad, enter: <Installer Code>...
  • Page 7 ® ® Introduction 3b) To reduce the brightness, press and hold down key B until the desired bright- ness is reached: 4) Press the ON key to adjust the active brightness and return to step 1a), or press the ENTER key to confirm the chosen levels, or wait a few seconds for the keypad to return to the inactive state.
  • Page 8: The Liquid Crystal Display (Lcd)

    ® ® Multifunction Control Panel The Liquid Crystal Display (LCD) During Standby status the display will show: 1st line: Date and Time 2nd line: Partition status (4 or 8 Partitions depending on the system). This line will also show: Trouble and Tamper — û û û û û will be shown above the respective icon; Special Functions —...
  • Page 9: Programming From The Lcd Keypad

    ® ® Programming from the LCD Keypad LCD K ROGRAMMING FROM THE EYPAD Customizing the System Installer Menu Options The Installer’s Code will allow you to access the INSTALLER MENU and program the following options: „ Actions (Event Logger, Zones Status, Test Siren, Clear Call Queue) „...
  • Page 10: Programming

    ® ® Multifunction Control Panel b) clear the alarm memory; WRONG CODE c) force all the outputs (Alarm and Open Collector) to standby status; d) stop the event evaluation; e) if necessary — interrupt the ongoing call, and put the Call queue on hold; f) activate the P light (slow blink) on LED Keypads.
  • Page 11: Zones

    ® ® Programming from the LCD Keypad Zones 1. From the Installer Menu, using C or D, select the PROGRAMMING Zones option, then press ENTER. Zones ßà Selecting the Zone 2. Using C or D, select the Zone, then press ENTER. Zones Zone 2 ßà...
  • Page 12 ® ® Multifunction Control Panel NOTE: If you assign the ‘Vibration’ or ‘Roller Zone 2 Blind’ attribute, you must select one of the fol- ßà lowing Balance types: „ BAL - Balance 1k5 (Balance using 1.5 Kohm resistor) „ NC - Normally Closed 7.
  • Page 13: Outputs

    ® ® Programming from the LCD Keypad Outputs 1. From the Installer Menu, using C or D, select the PROGRAMMING Outputs option, then press ENTER. Outputs ßà 2. Using C or D, select the Output, then press EN- Outputs TER. Output 2 ßà...
  • Page 14: Times

    ® ® Multifunction Control Panel Times 1. From the Installer menu, using C or D, select the Setting the Times: PROGRAMMING Times option, then press ENTER. Patrol Times ßà 2. Using C or D, select the required option, then press Listen.
  • Page 15 ® ® Programming from the LCD Keypad 6b. Repeat the procedure from step 4b, to program the other Time values for the selected Partition. Press ENTER to confirm the setting, or ESC to quit and go back to step 3b to continue.
  • Page 16: Installer Code

    ® ® Multifunction Control Panel Installer Code 1. From the Installer Menu, using C or D, select the PROGRAMMING Inst. Cod option, then press ENTER. Inst.Cod ßà 2. Enter the New Installer Code (4 to 6 digits) then Inst.Cod press ENTER to confirm and go back to step 1. ------ NOTE: The New Installer Code will not be valid until you exit the menu.
  • Page 17: X84; Wireless Option (If Selected At Step 2.)

    ® ® Programming from the LCD Keypad a) a long beep b) by an acceptance message which indicates New key the ID number (e.g. 009) PROGRAMMING c) by fast blinking on all 3 Reader LEDs 9a. Using ESC, go back to step 3. If the system does not Enrol the Key/Card (due to fault or system limitations —...
  • Page 18: Codes

    ® ® Multifunction Control Panel Codes 1. From the Installer Menu, using C or D, select the PROGRAMMING Codes option, then press ENTER. Codes ßà Code Number 2. Using C or D, select the Code Number (1 through Codes 24), then press ENTER. User Code 5 ßà...
  • Page 19: Readers

    ® ® Programming from the LCD Keypad Readers 1. From the Installer Menu, using C or D, select the PROGRAMMING Readers option, then press ENTER. Readers ßà 2. Using C or D select the Reader (1 through 16), Selecting the Reader Readers then press ENTER.
  • Page 20: Keypads

    ® ® Multifunction Control Panel Keypads If you are using a Control panel from the Kyo32 and Kyo8W Series, the application will present two sub-menus: “Program” and “Language”. In all other models you will access the “Keypad Programming” phase directly. 1.
  • Page 21: Date/Time

    ® ® Programming from the LCD Keypad Date/Time 1. From the Installer Menu, using C or D, select the PROGRAMMING Date/T. option, then press ENTER. Date/T. ßà 2. Using C or D, select the Day, Month, Year, Hour or Date/Time áâßà...
  • Page 22: Telephone

    ® ® Multifunction Control Panel Telephone 1. From the Installer Menu, using C or D, select the PROGRAMMING Teleph. option, then press ENTER. Teleph. ßà 2. Using C or D, select the Telephone Number Teleph. ID number (1 to 8), then press ENTER. Number 3 ßà...
  • Page 23: Teleservice

    ® ® Programming from the LCD Keypad Teleservice 1. From the Installer Menu, using C or D, select the PROGRAMMING Teleser. option, then press ENTER. Teleser. ßà 2. Using C or D, select the Rings option, then press Teleser. ENTER. Rings ßà...
  • Page 24: Events

    ® ® Multifunction Control Panel Events 1. From the Installer Menu, using C or D, select the PROGRAMMING Events option, then press ENTER. Events ßà 2. Using A or B select the Event, then press ENTER. This programming field will allow you to enter the Event number directly. ßà...
  • Page 25: Options

    ® ® Programming from the LCD Keypad Options 1. From the Installer menu, using C or D, select Op- PROGRAMMING tions, then press ENTER. Options ßà 2. Using C or D, select the required Option number, Options using ON or OFF, Enable or Disable the Option OFF ßà...
  • Page 26: Strings

    ® ® Multifunction Control Panel Strings This option will allow you to customize the descriptions of the system peripherals, etc. 1. From the Installer Menu, select the Strings option, PROGRAMMING then press ENTER. Strings ßà 2. Using C or D, select the relevant String (refer to Strings Table 4), then press ENTER.
  • Page 27: Default

    ® ® Programming from the LCD Keypad Default G G G G G - The default option will allow you to reset the Control panel to Factory Default, and delete the Events List. 1. From the Installer Menu, select the Default op- PROGRAMMING tion, then press ENTER.
  • Page 28: Input Expanders

    ® ® Multifunction Control Panel Input Expanders This option is available on Series 32 Models, and will allow you to program the Input Expanders. 1. From the Installer Menu, using C or D, select PROGRAMMING ‘Esp. IN’ then press ENTER. Exp.
  • Page 29: Programming From The Led Keypad

    ® ® Programming from the LED Keypad Programming from the LED Keypad Accessing Programming Only the following models from the Kyo range can be programmed via LED Keypad: KYO 4M KYO 4P KYO 8M KYO 8P All Partitions must be Disarmed before starting the programming session. 1.
  • Page 30: Programming

    ® ® Multifunction Control Panel Programming The following procedures are based on the assumption that you have already entered the Programming phase. Keypads Enrolling Keypads 1. To enrol one or more Keypads, ente the respective parameter number from through 8), then press ENTER. 2.
  • Page 31: Readers

    ® ® Programming from the LED Keypad Readers Enrolling Readers 1. To enrol Readers 1 to 8: enter 18, then press ENTER. NOTE: At this point, keys 1 to 8 correspond to Readers 1 to 8. To enrol Readers 9 to 16: enter 17, then press ENTER. NOTE: At this point, keys 1 to 8 correspond to Readers 9 to 16 (i.e.
  • Page 32: Setting Up The Zones

    ® ® Multifunction Control Panel NOTE: The ON, OFF, Slow or Fast Blinking status of each key deter- mines the status the respective Partition will adopt during A Mode (refer to “Meaning of LED/Key status” in Tab. 6). 3. Press ENTER to confirm, or ESC to abort the setting. NOTE: The Reader will not accept “Z”...
  • Page 33 ® ® Programming from the LED Keypad Assigning Zones 1. Enter a Parameter Number from 165 – 193 (refer to Tab. 7a for details), to Partitions then press ENTER. NOTE: At this point, keys 1 to 4 correspond to Partitions 1 to 4. 2.
  • Page 34 ® ® Multifunction Control Panel Cycles 1. Enter a Parameter Number from 166 – 194 (refer to Tab. 7a for details), then press ENTER. 2. Enter the required number of Cycles (refer to Tab. 7a). Accepted entries: 0 through 15 (0 = No cycles; 15 = Repetitive). If you enter a wrong value the Keypad will emit an audible error signal then allow you to retry.
  • Page 35: Setting Up The Outputs

    ® ® Programming from the LED Keypad Setting up the Outputs 1. Enter a Parameter Number from 191 – 210 (refer to Tab. 8 for details), then press ENTER. 2. Using keys 1 to 8, enable the required Activation Signal (refer to Tab. 8 for details).
  • Page 36 ® ® Multifunction Control Panel 7DE   287387 6(77,1*6 Parameter Accepted Parameter Description Meaning of LED Number Entries ON - Signal Enabled OFF - Signal Disabled - Valid Key - Superkey 2 Output Type and Signals - Missing BPI  - ?ed`ed ! - Reserved  - ?ed`ed "...
  • Page 37: Setting Up Times, Inactivity And Negligence

    ® ® Programming from the LED Keypad Setting up Times, Inactivity and Negligence Times 1. Enter the relevant Programming Address (refer to Tab. 9 — Programming Addresses 220 – 264), then press ENTER. 2a. Enter the required value (maximum 3 digits). The accepted values can be found in Tab.
  • Page 38: Telephone

    ® ® Multifunction Control Panel Telephone Setting up the 1. Enter a Parameter Number from 703 – 892 (refer to Tab. 10a for details), Phonebook (up to 8 then press ENTER. Telephone Numbers) 2. Enter the Telephone Number (maximum 20 digits). 3.
  • Page 39 ® ® Programming from the LED Keypad Central Station 1. Enter a Parameter Number from 723 – 912 (refer to Tab. 10a for details), Customer Code then press ENTER. 2. Enter the Customer Code (5 digits — 0 through 9). 3.
  • Page 40: Setting Up Teleservice And Test Event

    ® ® Multifunction Control Panel Setting up Teleservice and Test Event 1. Enter Parameter Number 283, then press ENTER. Callback and Double Call 2. Using keys 3 and/or 5, enable/disable the “Callback” and “Double Call” options (refer to Tab. 11 for details). 3.
  • Page 41: Events

    ® ® Programming from the LED Keypad Events Setting up the 1. Enter a Parameter Number from 919 – 1720 (refer to Tab. 12), then press Events ENTER. 2. Enter the Event Code, then press ENTER. IMPORTANT - The Event Codes are Decimal Codes (accepted en- tries: 0 through 255).
  • Page 42: Setting Up The Scheduler

    ® ® Multifunction Control Panel Setting up the Scheduler Linking Days 1. To set up the Scheduler, enter a Parameter Number from 2619 – 2664 with Partitions (refer to Tab. 13 for details), then press ENTER. 2. Using keys 1 to 7, link the respective days of the week with the Partition (refer to Tab.
  • Page 43: Options

    ® ® Programming from the LED Keypad Options Enabling Options 1. Enter a Parameter Number from 283 – 290 (refer to Tab. 14 for details), then press ENTER. 2. Using keys 1 to 8, enable the Options as required (refer to Tab. 14 for de- tails).
  • Page 44 ® ® Multifunction Control Panel Auto-Reset Memory 1. To set Auto-Reset Memory, enter 291 then press ENTER. 2. Using keys 1 to 4 (which correspond respectively to Partitions 1 to 4), en- able/disable the Auto-Reset Memory option (refer to Tab. 14 for details). 3.
  • Page 45: Codes

    ® ® Programming from the LED Keypad Codes Code Type 1. Enter a Parameter Number from 463 – 693 (refer to Tab. 15 for details), then press ENTER. 2. Using keys 1 to 3, define the Code Type (refer to Tab. 15 for details). 3.
  • Page 46: Programming Keys And Cards

    ® ® Multifunction Control Panel Programming Keys and Cards Programming 1. To program a new Key/Card, enter Parameter Number 5000, then press New Keys/Cards ENTER. The indicator will turn ON. 2. Enter the ID Number of the Reader you intend to use (accepted entries: 1 through 16), then press ENTER.
  • Page 47 ® ® Programming from the LED Keypad 7DE   352*5$00,1* 25 &+$1*,1* $ .(<&$5' Step no. Description Key Sequence Indicator ON Programming a New Key ÷ Select Reader (1 – 16) and/or (SERVICE, RESET CALL QUEUE, AND, Enable Key/Card Options PATROL Options) (for Partition 1) (for Partition 2)
  • Page 48: Extra Parameters

    ® ® Multifunction Control Panel Extra Parameters ATTENTION - The Extra Parameters are reserved for Factory program- ming purposes. 1. To program the Extra Parameters, enter a Parameter number from 265 — 280, then press ENTER. 2. Enter the respective Parameter Number, then press ENTER. Customized Protocol Parameters ATTENTION - The Customized Protocol Parameters are reserved for Factory programming purposes.
  • Page 49 ® ® Programming from the LED Keypad '(&,0$/+(;$'(&,0$/ &RQYHUVLRQ 7DEOH ± Dec. Hexa. Dec. Hexa. Dec. Hexa. Dec. Hexa. Dec. Hexa. Dec. Hexa.       &      %  '&       '    ...
  • Page 50 ® ® Multifunction Control Panel '(&,0$/%,1$5< &RQYHUVLRQ 7DEOH  ±  Binary Code Binary Code Binary Code Dec. Dec. Dec.                                        ...
  • Page 51 ® ® '(&,0$/%,1$5< &RQYHUVLRQ 7DEOH  ±  Binary Code Binary Code Binary Code Dec. Dec. Dec.                                                ...
  • Page 52 - infobentelsecurity@tycoint.com Recycling information BENTEL SECURITY recommends that customers dispose of their used equipments (panels, detectors, sirens, and other devices) in an environmentally sound manner. Potential methods include reuse of parts or whole products and recycling of products, components, and/or materials.

Table of Contents