LG 43SH7E Owner's Manual page 110

Monitor signage
Hide thumbs Also See for 43SH7E:
Table of Contents

Advertisement

36.
Tile Mode
Check (Command: d z)
Checks the tile mode.
Transmission
[d][z][ ][Set ID][ ][Data][Cr]
Data
FF: Check Tile Mode
Acknowledgment
[z][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]
Data 1 00: Tile Mode off
01: Tile Mode on
Data 2 00-0F: Tile column
Data 3 00-0F: Tile row
* This feature may not be available for all models.
37.
Tile ID
(Command: d i)
Sets the tile ID value of the product.
Transmission
[d][i][ ][Set ID][ ][Data][Cr]
Data
01-E1: Tile ID 1-225
FF: Checks the Tile ID
* The data value cannot exceed the value of row x column.
Acknowledgment
[i][ ][Set ID][ ][OK/NG][Data][x]
* If you enter a value that exceeds the value of row x column
for the Data parameter (except for 0xFF), Ack becomes NG.
* This feature may not be available for all models.
38.
Natural Mode
(In Tile Mode) (Command: d j)
To display the image naturally, the part of the image that
would normally be displayed in the gap between the monitors
is omitted.
Transmission
[d][j][ ][Set ID][ ][Data][Cr]
Data
00:
Off
01:
On
Acknowledgment
[j][ ][Set ID][ ][OK/NG][Data][x]
* This feature may not be available for all models.
39.
DPM
(Command: f j)
Sets the DPM(Display Power Management) function.
Transmission
[f][j][ ][Set ID][ ][Data][Cr]
Data
00:
Off
04: 1 minute
05: 3 minutes
06: 5 minutes
07: 10 minutes
Acknowledgment
[j][ ][Set ID][ ][OK/NG][Data][x]
* This feature may not be available for all models.
40. Remote Control/Local Key Operation Lock
(Command: k m)
Adjusts the remote control/local key (front) lock.
Transmission
[k][m][ ][Set ID][ ][Data][Cr]
Data
00:
Off
(Lock Off)
01:
On
(Lock On)
* When the monitor is turned off, the power key works even in
On (01) mode.
Acknowledgment
[m][ ][Set ID][ ][OK/NG][Data][x]
* This feature may not be available for all models.
41.
Power On Delay
(Command: f h)
Sets the schedule delay for when the power turns on. (Unit:
seconds)
Transmission
[f][h][ ][Set ID][ ][Data][Cr]
Data
00-FA: Min 0- Max 250 (sec)
Acknowledgment
[h][ ][Set ID][ ][OK/NG][Data][x]
* The maximum value may differ depending on the model.
63