Burners Injectors Replacement - Boschetti Industrie Meccaniche BGMTBAX 300 Manual For Installation And Use For User And Installer

Storage gas water heater stand on commercial low nox
Table of Contents

Advertisement

Burners injectors replacement

This operation must be carried out only by a qualified staff. You have to follows these directions:
- remove the cover for gas valve and unscrew the related fixing screws;
- dismount the burners protection mask;
- loosen in sequence: the thermocouple, the valve-pilot's gas tube and the valve-burner's gas tube;
- Unscrew the fixing screws and remove the support box with burners and pilot;
- remove the locknuts;
- dissamble with a suitable key the injectors of the burners and replace them with the right ones fixing the connections;
- set all the parts by following the opposite procedure.
- set the pressure to the injectors according to technical data scheme at page 4. (see paragraph at pag. 10 "Control
pressure outlet gas (Injectors pressure)").
Picture 14
Burners injectors replacement
Locknut
Burner's injector
Two burners
Locknut
Valve-burner's
gas tube
Burner's injector
IT
Boschetti Industrie Meccaniche srl
18
Ver. 01/2018