Troubleshooting; How To Proceed For Troubleshooting - Bosch Rexroth 50 NFF2 Operating Instructions Manual

Off-line filter system
Table of Contents

Advertisement

RE 51433-B/04.10 | 30, 50, 80 NFF2
12

Troubleshooting

12.1

How to proceed for troubleshooting

Always work systematically and focused, even when under time pressure.
f
Random and imprudent disassembly and readjustment of settings might result
in the inability to restore the original error cause.
First get a general idea of how your product works in conjunction with the
f
overall system.
Try to find out whether the product has worked properly in conjunction with the
f
overall system before the error occurred first.
Try to determine any changes of the overall system in which the product
f
is integrated:
Were there any changes to the product's operating conditions or operat-
ing range?
Were there any changes or repair works on the overall system (machine/sys-
tem, electrics, control) or on the product? If so: What were they?
Was the product or machine used as intended?
How did the fault become apparent?
Try to get a clear idea of the cause of the fault. Ask the direct (machine) op-
f
erator, if necessary.
Table 5:
Fault table
Fault
Cavitation
Pump is running on block
Pump does not deliver correctly Filter element contaminated
Pressure differential > 2.5 bar Suction line plugged
If you could not remedy the occurred fault, please contact one of the addresses
you find at www.boschrexroth.com or in chapter "16.1 Address directory".
Bosch Rexroth AG
Possible cause
Remedy
Incorrectly introduced
Correct the position
suction hose
Pressure hose plugged
Clear the pressure hose
Filter element contaminated
Exchange the filter element
Exchange the filter cartridge
Clear the suction line
Pressure line plugged
Clear the pressure line
25/30