Commissioning; First Commissioning - Bosch Rexroth 50 NFF2 Operating Instructions Manual

Off-line filter system
Table of Contents

Advertisement

RE 51433-B/04.10 | 30, 50, 80 NFF2
CAUTION!
CAUTION!
7

Commissioning

Missing seals and caps will lead to non-compliance with protection
class IP 54!
Liquids and contamination parts may penetrate and damage the product.
Before commissioning, ensure that all seals and plugs of the plug-in connec-
f
tion are leak-proof.
Product damage!
Polluted hydraulic fluid could result in wear and malfunctions. In particular, con-
tamination parts like e.g. welding beads or metal chips in the suction lines may
damage the off-line filter system.
When commissioning you should ensure absolute cleanliness.
f
7.1

First commissioning

7.1.1
Activating the hydraulic supply
Proceed as described in chapter "6.1 Assembling the off-line filter system".
7.1.2
Activating the electric supply
Proceed as follows to commission the off-line filter system:
1.
Switch on the 400 V AC supply voltage at the control box.
Bosch Rexroth AG
17/30