Resolving configuration errors

Learn about config logging information, iSCSI TOE adapter error log information (ICS_ERR template),
and iSCSI TOE protocol driver error log detail (ISCSI_ERR template).
This information might be useful for resolving configuration errors.

Config logging information:

It might be helpful to use the config log facility when trying to debug the iSCSI environment.
The most common error scenario is when cfgmgr -vl ics0 completes successfully, but does not create
any hdisks, or creates fewer hdisks than expected. Several common configuration errors can lead to this
scenario. The cfglog can be used to determine which of several common errors may have occurred.
You can run the following command to display any captured config log data:
alog -o -t cfg
To display information about the log file configuration, such as the location of the log file, run:
alog -L -t cfg
If config logging is not enabled, it can be enabled as follows:
export CFGLOG=""
echo "Create cfglog" | alog -t cfg
A useful debug method is to perform the following steps:
rmdev -Rl ics<x>
rm /usr/adm/ras/cfglog
echo "Create cfglog" | alog -t cfg
cfgmgr -l ics<x>
alog -o -t cfg
Some common errors will cause the open of the iSCSI protocol device driver to fail. In this case, the
cfglog will contain a message such as the following, where XX is an error number from errno.h
open of /dev/iscsi0 returned XX" where XX is an error number from errno.h.
The value returned by the open can indicate the problem. Two common values that can be caused by a
configuration error are 69 (ENETDOWN) and 70 (ENETUNREACH).
The return code 69 indicates that the link attached to the iSCSI adapter is physically down. Check to see
if the cable is correctly plugged in.
The return code 70 indicates that the link is up, but that the adapter was unable to obtain a client address
from DHCP. If the adapter's host_addr attribute is not set to a valid IP address, the adapter will attempt
to acquire an IP address from a DHCP server. If no DHCP server provides an IP address, the open will
fail with a return code 70.
After a successful open, the configuration method will attempt to start the device. If the SCIOLSTART
ioctl fails, it will prevent the discovery of the hdisks. A failure of SCIOLSTART will be recorded in the
config log as follows:
SCIOLSTART failed, errno = E, status_class = C, status_detail = D
If the values of C or D for the Status Class and Status Detail are nonzero, it indicates that the iSCSI login
failed. The Status Class and Status Detail are values returned in the iSCSI login response. The meaning of
the Status Class and Status Detail values are documented in the iSCSI RFC 3270.
100