Clearing All Error Code; Cancelling The Self-Diagnostic Mode; Setting Of Doctor Mode - Panasonic SA-PM21PC Service Manual

Table of Contents

Advertisement

SA-PM21PC
No.
3
[
] key is pressed, after loading a NORMAL,
CrO2, METAL type cassette with the recording
tab on the right side removed.
4
[TAPE
NORMAL, CrO2, METAL type cassette (
cassette for TPS checking purposes and with
both recording tabs intact ).
5
[REC] key is pressed, after loading in a
NORMAL type cassette ( with both recording
tabs intact )
6
Self-diagnostic mode is stopped by pressing
the [STOPn] Key.
7
To clear all the abnormalities in the memory,
press the [STOPn] Key for more than 5 Sec
while the self-diagnostic mode is stopped.
8
To cancel the self-diagnostic mode press the
[POWER] Key.
· As HALF SW solder point and RECINH SW solder point are located close to each other, it's necessary to check the shorting
between the adjacent points. For this purpose, operation has to be executed twice using two kind of cassettes, i.e. a cassette
with recording preventive tabs for both Sides A/B and a cassette with a recording preventive tab for only either one side of Side
A/B.
12.1.5. Error Code for CD Mechanism
Error code
Possible symptom
H01
DECK operation
abnormal (reel motor,
solenoid, and MODE
SW)
F15
CD REST_SW
abnormal
H15
CD OPEN_SW
abnormal
F26
Communication
between CD servo LSI
and microp abnormal

12.2. Clearing all error code

1. Press and hold STOP button for 5 seconds.
2. FL indicator shows "CLEAR" for 1 second and change to "TEST".

12.3. Cancelling the Self-Diagnostic mode

1. Press the "Power" button to turn off the system. Press the "Power" button again to turn on the system.

12.4. Setting of doctor mode

1. At any more (CD, TAPE, TUNER).
Operation Procedures
] Key is pressed, after loading in a
Possible cause
· During normal operation, if mechanism error process is executed once by mode switch against the
same deck operation, it is judged as mechanism abnormality and this is memorized as an error.
· Conditions for judging mechanism error:
− Mode switch ON is not detected 800 ms after plunger activation for PLAY / REC process.
− Mode switch ON is not detected 800 ms after plunger activation for FF / REW process. Or, Mode
switch OFF is not detected 800 ms after plunger activation after detecting Mode SW ON. Or,
Mode Switch ON is not detected 800 ms after detecting Mode switch OFF.
− If Mode switch comes ON at STOP / PAUSE state (normal condition), this is judged as an Error:
1. Main purpose for this Self Diagnosis is to diagnose a partial short of the deck.
2. Mechanical error process caused by EJECT operation will not be counted.
3. This error number can be cleared only at the start up of micro-p reset.
· At initial setting of CD traverse position, if REST SW ON is not detected even though the fail safe
timer time is over (10 sec), this is memorized as an error and the error number can be cleared only
at the start up of micro-p after reset.
· During normal operation, if CD OPEN SW ON is not detected within 4 sec, then H15 will be
memorized in memory. The error code can be cleared only at the start up of micro-p after reset.
· At the time of switching to CD function, SENSE = H will be detected using DTMS system setting
command. If the error is memorized when SENSE = L is not detected within fail safe timer time (20
sec), [F26] will be displayed simultaneously. This display will be retained if the power is ON and at
CD function. If this error occurs, CD operation afterward cannot be executed as in the case of
[NO.DISC.].
· This error number can be cleared only at the start up of micro-p after reset.
Micon operation & processing
REW shall be executed for 2 sec, afterwhich STOP.
Check the following.
{ F.REC INH SW } is ON
{ HALF SW } is ON
Reel pulse toggles between H & L.
TPS operation is executed. Check the following.
{ F.REC INH SW } is ON
{ HALF SW } is ON
TPS signal changes.
After checking TPS, it shall STOP.
If TPS checking is completed at TAPE END, it is considered as TPS
abnormal.
REC operation shall not be executed.
Check the following.
{ F.REC INH SW } is ON
{ HALF SW } is ON
LCD shall display the abnormality item code, when the STOP key is pressed,
it shall display the abnormality item code in the following sequence.
[ TEST H 0 1 ] [ TEST H 0 2 ] [ TEST H 0 3 ]
At this time, all the abnormalities item in the memory is cleared and is
displayed on the LCD.[ C L E A R ] display for 1 Sec. then,[ TEST ] is
displayed.
POWER is OFF.At the next POWER ON, normal operation shall be executed.