End position „DOWN"
[35] There are two possibilities for con-
firming end position „DOWN":
• 10 seconds after reaching the
closed position automatically or
• by pushing of button 3 or 4.
Once the end position „DOWN" is
learned, the drive lamp flashes
twice, subsequently the door is run
automatically into opened position
again.
Force in „UP"-direction
[35] During run into end position „UP"
the control learns the force auto-
matically. The drive stops automati-
cally, once the end position „UP" is
reached. For confirming the
learned force, there are two possi-
bilities:
• 10 seconds after reaching the
opened position automatically or
• by pushing button 3 or 4.
Once the force values in „UP"-di-
rection have been saved, the drive
lamp flashes once, subsequently
the door is run into closed position
automatically.
Force in „DOWN"-direction
[35] During run into end position
„DOWN", the control is learning the
force automatically. The drive stops
automatically, once the end posi-
tion „DOWN" is reached. At the
same time the force values in
„DOWN"-direction are saved. 2
seconds after reaching the end po-
sition „DOWN", the door is auto-
matically run into opened position
in order to avoid locking out the fit-
ter from the garage.
After finishing the above-described
learning runs, only the learned button is
active, see paragraph „Hand-held trans-
mitter operation".
Learning without transmitter
End position „UP"
[36] Unlock western plug with yellow
bridge (6) and pull out.
[37] Activate „Impulse" button (1) and
keep it pushed. The door moves to
open. Release the „Impulse" button
as soon as the desired end posi-
tion „UP" is reached.
[38] Plug western plug back in.
A correction of end position „UP" in
closing direction is possible now by
means of the „Impulse" button.
48
[39] Confirm reached end position „UP"
by pushing the „Program" button
(2), the drive lamp flashes 3 times.
Once the end position „UP" is
learned, the door is run automati-
cally in closing direction. The door
drive stops automatically, if the
right closed position is reached.
End position „DOWN"
There are two possibilities for con-
firming end position „DOWN":
• 10 seconds after reaching the
opened position automatically or
[39] • by pushing the „Program" button
(2).
Once the end position „DOWN" is
learned, the drive lamp flashes
twice, subsequently the door is run
automatically back into opened po-
sition.
Force in „UP"-direction
During run into end position „UP"
the control learns the force auto-
matically. The drive stops automat-
ically, once the end position „UP" is
reached. For confirming the
learned force, there are two possi-
bilities:
• 10 seconds after reaching the
opened position automatically or
[39] • by pushing the „Program" button
(2).
Once the force values in „UP"-di-
rection have been saved, the drive
lamp flashes once, subsequently
the door is run into closed position
automatically.
Force in „DOWN"-direction
During run into end position
„DOWN", the control is learning the
force automatically. The drive
stops automatically, once the end
position „DOWN" is reached. At
the same time the force values in
„DOWN"-direction are saved. 2
seconds after reaching the end po-
sition „DOWN", the door is auto-
matically run into opened position
in order to avoid locking out the fit-
ter from the garage.
Checking obstruction
safeguard
The obstruction safeguard is safety
equipment that protects against crush-
ing, and should prevent injuries caused
by the closing door (static switching-off
force: 150 N).
[40] Perform test run:
Stop door from outside with both
hands in hip height. During closing
procedure, the door has to stop au-
tomatically and run back about 30
cm, if it meets resistance. During
opening procedure it has to stop
automatically, if it is held back.

Operation

Instruct all persons, who are in-
volved in using the door equipment,
with respect to safe and proper opera-
tion of it.
There is a risk of injury due to crush-
ing or cutting at the closing edges
and with the mechanical device. Open
and close the door only when you can
see the area of movement of the door
and when no people are in the imme-
diate vicinity!
Hand-held transmitter
operation
Keep transmitters away from
children. Activate the hand-held trans-
mitter only, if you can see the door
area well. Watch the moving door and
keep persons away, until the door is
completely closed or opened.
Learn transmitter
The topmost button of the hand-held
transmitter is learned for the radio re-
mote control by the manufacturer al-
ready. If you want to learn a further but-
ton of the transmitter or a second trans-
mitter, proceed as follows (for learning,
hold transmitter as close as possible to
the drive head):
[41] Push „Program" button (2) briefly –
the red LED (3) flashes once: Acti-
vate within 20 seconds a not-
learned transmitter button – the red
LED lights continuously (learning is
finished).
In case of wrong learning, the radio
commands can be reset again, see [46].
For putting further hand-held transmit-
ters into operation, repeat the entire
learning procedure and proceed as
aforesaid.