V-Flow Line Contents Introduction Service and quality Warranty General instructions Safety information Using the manual General information Operating principle of the variable area flowmeter Variable area flow meter type marking High-precision control valve type marking Technical data Technical data Q-Flow Materials Q-Flow Setups Q-Flow Technical data V-100...
Page 4
V-Flow Line Disassembly and maintenance Important instructions Disassembly variable area flowmeter Q-Flow Disassembly variable area flowmeter V-100 Disassembly Digiturn M-Flow Maintenance Soiling Cleaning Return Appendix Dimensions Q-Flow Dimensions V-100 Dimensions M-Flow Type code Q-Flow Type code V-100 Type code M-Flow Contamination declaration Manual Version...
V-Flow Line Introduction We are glad that you have decided to use our variable area flow meters and high-precision control valves. Our instruments will provide you with high-quality long-lived products. This manual contains important information for commissioning and/or designing equipment. Please contact your distribution partner if anything is not clear.
V-Flow Line General instructions Check the package for external damage and contact your distribution partner if the instruments have visible defects. Check that the delivery is complete and corresponds to the delivery note. This product is a precision measuring instrument. We would like to point out that you should take due care when choosing the installation site and following these suggestions and instructions.
V-Flow Line General information Operating principle of the variable area flowmeter The measuring instrument works according to the float measuring principle The measuring unit consists of a tapered graduated precision glass measuring cylinder in which a ball float can move freely up and down. The medium flows through the vertically-aligned measuring cylinder from the bottom upwards.
V-Flow Line Variable area flow meter type marking The instrument type label is attached to the inside of the left side panel in the V-100 and on the back of the mounting plate in the Q-Flow: Example: 483493-1-006 07/08 133526 Type: FLV-CSSA-SM Air, 3.6-43 ln/min, 4 bar a, 20°C...
V-Flow Line Technical data Technical data Q-Flow Type Q-Flow 55 Q-Flow 80 Q-Flow 140 Turndown ratio 10:1 10:1 10:1 Accuracy in % of full scale ± 5 % ± 4 % ± 2 % Measuring tube length 55 mm 80 mm 140 mm Scale length 40 mm...
V-Flow Line Technical data V-100 Type V-100 55 V-100 80 V-100 140 Turndown ratio 10:1 10:1 10:1 Accuracy in % of full scale ± 5 % ± 4 % ± 2 % Measuring tube length 55 mm 80 mm 140 mm Scale length 40 mm 65 mm...
V-Flow Line M-Flow valve operation options The following valve operation options are available (see also the type code of each instrument): Standard-knob Standard-knob with locking ring manual knob manual knob stop ring 518-1552 basic valve right- or left-handed disc Ø10x6.4/0.5 518-1550 thread made from brass or headless screw M3x6 512-8204 headless screw M3x6 512-8204...
V-Flow Line -values high-precision control valves M-Flow -values valves NS1.0 to NS6.5 0.01 0.001 0.0001 NS-1.0 NS-1.5 NS-2.0 0.00001 NS-2.5 NS-3.0 NS-4.0 0.000001 NS-6.5 0.0000001 spindle turns /h water at Δp of 1bar -value 1 = 1 m Manual Version Page V-Flow Line vflow_E4_7...
V-Flow Line Installation and commissioning General instructions Measuring instrument design In addition to the type code (see appendix) we require you to supply the following information for optimal design of the instrument: Medium Maximum flow rate For design without valve: Pressure in measuring cylinder ...
Page 17
V-Flow Line What is the purpose of standard liters and norm liters? In contrast to liquids, gases can be compressed, so it is important to know the density of the gas used. This in turn is dependent on pressure and temperature, i.e. if two quantities of gas are to be compared with one another, then the current pressure in the pipe and the current temperature of the medium must be known.
V-Flow Line Installation instructions Before installing the measuring instrument, the pipe must be free of particles and moisture The variable area flowmeter must be installed in a vertical position The direction of flow is from the bottom upwards ...
V-Flow Line Panel mounting Q-Flow For mounting, the panel opening must be prepared according to the diagram Screw the two mounting brackets onto the instrument as shown Screw the setscrew supplied into the connector and insert the instrument into the aperture from the front ...
V-Flow Line Faceplate mounting V-100 For mounting, the faceplate must be prepared according to the diagram The instrument is supplied with mounted plate and inserted into the aperture from the front. Screw the plate to the control cabinet using suitable M3 screws ...
V-Flow Line Limit indicator The V-100 variable area flowmeters can be equipped with a maximum of two limit indicators. The instruments with limit indicators have the following standard design: Minimum Switch Maximum Switch Initiator position Switching status Note: In case of power failure, the contact closes irrespective of the position of the float. For initialization, the float must first pass the initiator so that it is recognized by the initiator and the float position is defined.
Page 22
V-Flow Line Setting the limit indicator Remove the front glass (1) Unscrew both clamping screws (2) Position the limit indicator Tighten the clamping screws Fit the front glass For retrofit installation of a limit indicator the measuring glass must be removed.
Page 23
V-Flow Line Minimum spacing for limit indicators To ensure that the limit indicators do not interfere with one another a minimum space must be complied with. Installed vertically in a measuring instrument: Measurement instruments adjacent to one another: A = Minimum 16 mm B = Minimum 6mm Areas of application Limit indicators only work with steel variable area flowmeters.
V-Flow Line M-Flow Digiturn installation Slide the adjusting ring 518-1563 onto the valve (do not tighten yet) Slide the adapter sleeve 518-1575 onto the valve axis and tighten the setscrews 512-8202 Slide the rear part of the hand knob onto the adapter sleeve again. The pin on the knob must be pushed into the hole in the adjusting ring completely so that no gap remains ...
V-Flow Line Disassembly and maintenance Important instructions Close the valves before and after the measuring instrument Close the needle valve on the measuring instrument Caution When disassembling the measuring glass, residual liquids or gases may escape. As the float is loose inside the measuring glass, care must be taken when removing it so that the float is not lost.
V-Flow Line Disassembly variable area flowmeter V-100 Remove the screws (1) and Plexiglas (2) Unscrew the locking screw (3) while holding the measuring glass firmly (hexagon socket, key size 5 mm) If the screw is loosened sufficiently, then the measuring glass can be removed Refitting Refitting is carried out in the reverse sequence: ...
V-Flow Line Disassembly Digiturn M-Flow Close the rotary knob or valve until the scale shows 00.00 Open the cover ring 633-1104 and remove from the rotary knob Unscrew the M5x5 setscrew. The back part of the knob can be pulled off (hexagon socket, key size 2.5 mm) ...
V-Flow Line Maintenance When used correctly, variable area flow meters from Vögtlin Instruments AG do not require any maintenance. Soiling The following symptoms indicate soiling: The set value can no longer be reached – the control valve is probably soiled ...
V-Flow Line Dimensions V-100 Type Dimensions in mm 120.5 89.5 61.5 V-100 55 145.5 114.5 86.5 V-100 80 205.5 174.5 146.5 V-100 140 Fitting Thread depth G 1/4“ female G 1/8“ female NPT 1/4“ female G 1/4“ female for compression fittings Manual Version Page...
V-Flow Line Dimensions M-Flow M-Flow 25 straight valve Fitting Dimensions in mm Thread depth G 1/4“ female G 1/8“ female NPT 1/4“ female G 1/4“ female for compression fittings M-Flow 25 corner valve 8xM4 depth 4mm Fitting Dimensions in mm Thread depth G 1/4“...
V-Flow Line Contamination declaration With return of devices, please fill out the following statement completely, especially the reason for the return, the type of residue and cleaning in the case of soiling, as well as indication of hazards. Device: Type code: Serial number: Reason for return: Type of contamination...
Page 38
V-Flow Line Change log Date Version Replaces Author Note 01.03.2010 vflow_E4_3 vflow_E4_2 Page 21 / New Article Code 17.01.2011 vflow_E4_4 vflow_E4_3 Page 12, 21, 29, 30, 31, 32: Translation of marking Page 9, 10: Material of limit stop added 07.05.2012 vflow_E4_5 vflow_E4_4 Page 18 / Sealing Material...