CONTROL POINTS
Control
Point
Description
Number
23
Sequencing
Sealed Control Point
24
Sealed Control Point
25
*Push-open/
push-closed function
26
Cycle Counter
27
Sensor detection zone
24
Value
Factory
Range
Setting
0
DO NOT
CHANGE
0
DO NOT
CHANGE
1 or 0
0
on/off
0 –
00
655355
0 – 60
45
Comments
Sequencing (Consult Factory)
1 = A doorway has a pair of doors, one active,
the other inactive. The active door is equipped
with an astragal (lip). The active door must open
first; the inactive door must close first.
NOT USED
This feature is used when it is inappropriate to
specify a door opening time, because of a
requirement to hold the door open for a long
period of time.
0 = Normal operation (impulse opens door; door
closes automatically)
1 = An impulse opens the door. The Operator
holds the door open until either:
If the door opening time is set to 59 sec. or
less in Control Point 07, 16 or 17, the door
closes automatically when the door opening
time expires;
or
* If the door opening time is set to 60 sec in
Control Point 07, 16 or 17, the door does not
close until a second impulse is received.
The counter displays the number of times the
door has cycled (opened and closed), scrolling
two digits at a time starting from the left.
A safety sensor can be mounted on the door. This
sensor monitors a detection zone, and stops the
door when it detects an obstruction. The detection
zone changes continually as the door moves through
its swing path. If, for example, there is a wall
adjacent to the door, the sensor may detect the wall
and stop the door before it reaches the fully open
position. To prevent this, you can deactivate the
sensor just before it reaches the opening angle at
which it would detect the wall. Use this Control Point
to specify this angle.