Sargent 2600 Series Instructions For Installation Manual page 24

Low-energy swing door operator
Table of Contents

Advertisement

Control
Point
Description
Number
16
Door hold open time:
Push and Go
17
Door hold open time:
Delayed impulse
18
Operation of latching
device relay
19
Stall feature
(Closing Direction)
20
Hold-open force
Wind Condition
21
Latching device unload
force
22
Latching device relay
hold time
Value
Factory
Range
Setting
0 – 60
8.0
The time period for which the door will be held
sec
at the fully open position when the Push and Go
feature is active (Control Point 13 is set to 1).
• For a typical Push and Go application, the door
0 – 60
15
The time period for which the door will be held
sec
at the fully open position when a delayed impulse is
received by the Operator.
• For a typical push-plate application, the door
1 or 0
0
A latching device can be controlled by the Operator.
on/off
0= In Auto mode, when the Operator receives an
impulse, the latching device relay is activated and
the latching device is energized.
1= In Auto mode, when the Operator receives an
impulse, the latching device relay is not activated
and the latching device is not energized.
1 or 0
0
Selection of obstruction sensitivity feature operation
on/off
in closing direction.
0= The door stops and does not move.
1= The door stops, then reopens to the fully
open position.
• See Control Point 12.
0 – 10
0
While the door is fully open, the Operator holds it
relative
against the door stop to prevent the door from
moving, for example because of wind pressure.
0 = No force
10 = Maximum force
• Specify this setting after the fully open position
0 – 10
0
While the door is in the fully closed position and
relative
receives an "open" impulse, the Operator forces the
door against the frame stop for 1 sec, making it
easier for the latch to release.
0 = No force
10 = Maximum force
1 – 10
2
This setting controls the length of time that the
sec
lock control relay is activated.
• In a fire door application, the latching device
• Used for latch retraction devices or electric
CONTROL POINTS
Comments
opening time should be 10 sec.
opening time should be 15 sec.
has been established. See Control Point 01.
relay hold time should be set to the minimum.
strikes.