Connection of domestic hot water tank temperature sensor
● Put the sensor holder thread (15A) into the domestic hot water tank screw hole (15A).
● Push domestic hot water tank temperature sensor into the cap hole of the sensor holder.
● Lock the sensor holder cap.
● Connect the sensor cable to the terminal of domestic hot water tank temperature sensor
in the indoor unit.
T/B5
1-1 1-2 2-1 2-2
28
Inverter Hybrid Boiler
Domestic
Hot Water
Tank Temperature
Sensor
PT15A female screw
Domestic Hot Water
Tank Temperature
Sensor
PT15A
Domestic hot water tank
Inside of domestic
hot water pump
Sensor holder