Please read carefully before use and follow the instructions correctly. Please retain this user’s manual for future reference after reading it carefully. This manual can be downloaded from the website. http://www.carrier.co.kr/support/aircon_manual.asp P/N : 60WHD025-540010 | Inverter Hybrid Boiler | Hydro Unit (Indoor unit) User's...
In case of malfunction, the self-diagnosis function displays error messages on the wired remote controller. function │ │ Inverter control Carrier's advanced energy saving inverter technology always operation ensures a comfortable indoor environment. │ │ Improved convenient Repeat hours, quiet mode, outing mode are adopted for user convenience.
Page 3
Table of Contents Safety Precautions ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥ Operating Method How to use a wired remote controller ‥‥‥‥‥‥‥‥‥‥‥ Prior to Use How to operate a wired remote controller ‥‥‥‥‥‥‥‥‥‥ Scope of operation ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥ Things to Troubleshooting and Checklist ‥‥‥‥‥‥‥‥‥‥‥‥‥‥ Be Aware of Checklist before making a request for technical support ‥‥‥‥...
When using the product Warning Do not touch the main power Do not put your finger or a stick into the air inlet and outlet while the switch with a wet hand equipment is in operation. (may cause electric shock and failure) Wet Hand Prohibited (may cause an injury, as the fan inside...
Page 5
When using the product Warning If you notice a strange smell or Do not turn off the power switch sound coming from the product, stop or pull out the power cable during the operation, turn off the power and operation. Power Off Prohibited contact the authorized service center.
Page 6
When using the product Caution Do not spray insecticide or Do not step up or put anything flammable materials during on the product. operation. (may cause failure) (may cause failure, electric shock or Prohibited Prohibited injuries from falling) Do not disassemble, repair or Do not use a wax, thinner or solvent modify the product arbitrarily.
Page 7
When using the product Caution Turn off the main power switch if you are not planning to use the product for an extended period of time. Power Off (can prevent an unexpected accident.) Do not turn the power off during the winter season, even if the boiler is not in use.
Page 8
When using the product Caution Do not place any heat source near Do not modify the protection device the product. or change its settings. (may cause a fire or electric shock) (may cause a fire or explosion if other Mandatory Prohibited protective devices such as pressure switch or temperature switch are...
Page 9
When using the product Caution Ensure that any interruption to the power supply during winter is resolved as quickly as possible, as an extended blackout in the winter season affect Mandatory the anti-freeze function. (deactivated anti-freeze function may cause freezing and bursting of tubes and pipes in the product) Be careful not to let your skin touch the outlet of the heating section.
Page 10
When you use the product Warning Precautions when using the remote controller ● Do not place any heat source near the product. - It may cause a fire. ● Do not spill water inside the product. - It may cause an electric shock or failure. ●...
Page 11
Button names of wired remote controller Power supply Display Inverter Hybrid Boiler Operating Mode Display Set Temperature/Current Temperature Display Operating Status Display Temperature / Repeat Time adjust Button Operation on/off Domestic hot water tank Thermal Storage Room Temperature Setting Room Temperature Setting Tank Silent Operation Setting...
Page 12
Display of wired remote controller Silent Operation Repeat Operation Outing Operation Heating Operation Domestic Hot Water Tank Temperature / Test Operation Domestic Hot Water Tank Temperature Settings Room Temperature/ Room Temperature Settings Repeat Time Compressor 1 (Outdoor Unit) Operation Low Level Warning Compressor 2 (Hydro Unit) Anti-freeze Operation Operation...
Heating operation This function increases the flow temperature in the indoor unit (hydro unit). It provides heat to indoors through the floor heating coil or radiators. ● The automatic heating operation is activated when pressing Inverter Hybrid Boiler the ON/OFF( ) button.
Domestic hot water tank temperature Setting ● To set the domestic hot water tank temperature, press the DHW button first, and press the TEMP/TIME adjust buttons (▲, ▼) to Inverter Hybrid Boiler adjust the temperature setting. - You can adjust the temperature setting by 1℃ per one time pressing in a range from 35 to 80℃.
Outing operation ● Outing mode is activated when you press the OUTING button. Inverter Hybrid Boiler - " " appears on the operating mode display. - The domestic hot water tank temperature and the room temperature for outing mode are set to 80℃ and 20℃, respectively.
Scope of operation Operating conditions ① The temperature range that will ensure the normal operation of the product is as follows. Ambient temperature of ~ 40 ℃ ℃ the outdoor unit Ambient temperature of ~ 40 ℃ ℃ the hydro unit ②...