Sensor Adjustment; Weigh Bin Door Flow Control Adjustment - Maguire Products S-BLENDER Supplimental Documentation

Table of Contents

Advertisement

Maguire S Blender

Sensor Adjustment

Location: Below the weigh bin door, next to the mix
motor. Calibration: With the mix chamber EMPTY,
press and hold the button located on the Sensor using a
pen. Continue to hold the button until the sensors green
light blinks TWICE then release the button. Be sure to
release the button before the green light blinks 5 times
or you will have to calibrate sensor again. Note: Do not
clean glass prior to calibrating. Calibrate with
material dust present. Sensor air gap between sensor
and glass should be approximately 3/16" (5 mm).
Sensor Lights: Green light is power, should always be
on solid when dryer has power (unless calibrating).
Yellow should be on when no material is present in the
mix chamber and off when material is present in the mix
chamber. Red indicates a problem with a sensor or mis-
calibration.

Weigh Bin Door Flow Control Adjustment

The Weigh Bin Flow Control is located below the
Controller Tray and accessible from the left side. This
pneumatic adjustment adjusts the closing rate of the
Weigh Bin's dump valve. Adjust this valve so that the
weigh bin valve closes firmly but does not slam closed.
Proper adjustment of the Weigh Bin Flow Control is
important so that damage does not occur to the Weigh Bin
parts.
To ensure accurate dispense additive
Material, the additive Slide Gate is
intentionally restricted in how far it can
open. This is by design. Do not attempt to
adjust.
10
Maguire Products, Inc.