Alemite 7216-S Service Manual

Stainless transfer pump.

Advertisement

Quick Links

Description
NOTE: The components within the fluid-wetted
path of this pump are stainless steel and Teflon.
This pump is tested in mineral oil. Flush the pump thor-
oughly with a solvent compatible with the product dis-
pensed as required.
The major components of pump model 7216-S3 consist of a
reciprocating differential air motor and a double-acting pump tube.
This low-pressure (1:1 ratio) pump is equipped with a
2 " PT (m) bung adapter and a stainless extension that allows
operation directly from original 55-gallon (200/205 l) drums.
Models 7216-S and 7216-S3
Model 7216-S is obsolete. Repair parts are still available.
Specifications
Differential Air Motor
Piston
Effective
Diameter x Stroke
Piston Area *
2
In
Cm
In
2-1/16 x 4
5.2 x 10.2
1.67
For details on the air motor, refer to Service Guide SER 318450-4.
See Figure 3 for performance curves.
* The effective piston area of a differential air motor is equal to one-half the
actual area of the piston.
Pump Tube
Max. Fluid
Pressure
Fluid
Outlet
psi
Bars
1 " NPTF (f)
200
13.8
See Figure 3 for performance curves.
* SAE 10 oil at 75 ° F (24 ° C) and 100 psi [6.9 Bars] air pressure.
Table 1 Transfer Pump Model 7216-S3 Specifications
This document contains confidential information that is the property of Alemite Corporation
670547
and is not to be copied, used, or disclosed to others without express written permission.
Service Guide
Stainless Transfer Pump
CAUTION
Maximum Air
Air Inlet
2
Cm
10.8
1/4 " NPTF (f)
Max. Free-Flow
Delivery/Minute *
Gallons
Liters
In
14
53
10.5
Alemite Corporation
PO Box 473515, Charlotte, North Carolina 28247-3515
www.alemite.com
©
Copyright
Pressure
psi
Bars
200
13.8
Displacement
per Cycle
3
3
Cm
172
Figure 1 Stainless Transfer Pump Model 7216-S3
2002 by Alemite Corporation
7216-S
7216-S3
SER 7216-S3
Revision (10-02)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7216-S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alemite 7216-S

  • Page 1 PO Box 473515, Charlotte, North Carolina 28247-3515 www.alemite.com © Copyright 2002 by Alemite Corporation SER 7216-S3 This document contains confidential information that is the property of Alemite Corporation 670547 Revision (10-02) and is not to be copied, used, or disclosed to others without express written permission.
  • Page 2 SER 7216-S3 Stainless Transfer Pump Figure 2 Transfer Pump Model 7216-S3 - Exploded View Revision (10-02) Alemite Corporation...
  • Page 3 Extension (Stainless Steel) 338598 (21) Legend: Part numbers left blank (or in italics) are not available separately designates a repair kit item SS = Stainless Steel Repair Kit Part No. Kit Symbol Description 393309-2 Kit, Major Repair Alemite Corporation Revision (10-02)
  • Page 4: Performance Curves

    The curves relate delivery in gallons (liters) per minute (X axis) to air consumption in cubic feet (liters) per minute (right Y axis) and to fluid discharge pressure in psi/Bars (left Y axis). Figure 3 Delivery versus Discharge Pressure and Air Consumption Revision (10-02) Alemite Corporation...
  • Page 5 Air Motor’s piston rod as required. 4. Remove Cotter Pin (6) that secures the Air Motor’s piston rod to the Rod and Stop Assembly. 5. Unscrew the Rod and Stop Assembly from the Air Motor’s piston rod. Alemite Corporation Revision (10-02)
  • Page 6: Clean And Inspect

    Plunger. • additional Washer (10)........Qty 1 • Use care not to damage the Packing Rings. Item No. Description Air Motor piston rod bore of Cylinder Table 3 Components Lubricated in Clean Mineral Oil Revision (10-02) Alemite Corporation...
  • Page 7 Stainless Transfer Pump SER 7216-S3 Refer to Figure 2 Parts List for Parts Identification Figure 4 Pump Tube Assembly - Section View Alemite Corporation Revision (10-02)
  • Page 8 9. Slowly supply air pressure to the pump’s motor. 10. Allow the pump to cycle slowly until the fluid is free of air. If the pump assembly does not prime, refer to the Troubleshooting Chart for details. Revision (10-02) Alemite Corporation...
  • Page 9: Installation

    5. Set the air pressure to 30 psi (2.1 Bars). 6. Hold the control valve open while aiming into a suitable collection container. 7. Loosen the Packing Screw Assembly until the pump assembly begins to cycle. * Applies to new and overhauled pumps. Alemite Corporation Revision (10-02)
  • Page 10: Troubleshooting Chart

    4. Worn or damaged Valve Body (25) inspect, and replace worn or damaged 5. Worn or damaged Valve (19) components 6. Worn or damaged Plunger (21) Changes Since Last Printing Deleted Minor Repair Kit to 393624 Revision (10-02) Alemite Corporation...