Example of a cubicle without starter
Action
Check that the electrical connections correspond to the local codes. The installation must
be earthed and protected by fuses in all phases. An isolating switch must be fitted.
Check the wires on transformers (T1/T2) for correct connection.
Check the setting of the circuit breakers (see the section Settings of circuit breakers).
Action
Check that the cooling water drain valves (customer's installation) in the inlet and outlet
lines are closed.
Check that the water shut-off valves (customer's installation) are open.
Open the water regulating valve and check for water flow.
Instruction book
2920 1796 01