LIMIT SWITCH - ADJUSTMENT

After checking the phase rotation, the limit switches must be adjusted in the following steps.
When open and close position limits have been set the safety limits are automatically
pre-adjusted. Eventually fine adjustment could be required. Please see Mechanical
Operating Instruction.
1. Move the door to final open position
Door open
press button to reach upper limit
2. Adjustment final open limit
After reaching the final open
position the limit S3 must be
switched with green limit cam S3
and panel display changes to
„Door final open position"
3. Move the door to final close position
Door close
press button to reach lower limit
4. Adjustment final close position
After reaching the final close
position the limit S4 must be
switched with green limit cam S4
panel display changes to „Door
final close position"
Working limit adjustment is complete
The door could be moved in DEADMAN mode UP/DOWN
Further adjustments see programming mode (Page 16)
Display
shown - door
between final
limit positions
Display shown-
door open
Display shown-
door between
final limit
positions
Display shown-
door closed
Page 13
Display flashing
during the door
upwards movement
Display flashing
during door
downwards
movement