ADJUSTMENT: AUXILIARY FUNCTIONS
After adjustment of the automatic close feature the display shows Auto close LI, photo-beam
interruption.
Auto close
yes < >
OK
Adjustment relay contact 1, pre-information mechanical limit NES
operation
This will be shown after automatic close feature
relay contact
adjustment
OK
This menu only appears when a photo-beam is
LI
installed and the timer to close is set. If the closing
no
OK ?
cycle is required to start immediately after the pho-
to-beam has been interrupted and re-made use the
arrowed buttons UP and DOWN to set the >> arrow
before yes.
ESC
If the closing delay timer should not be interrupted
set the >> arrow before no and confirm OK.
See description relay contact (page 16). The
1
TS 980 has 2 potential free relay contacts available
OK ?
that can be chosen for several functions. When using
mechanical limits (NES) only a reduced function is
available.
In this operation mode only one pre-warning signal
ESC
light can be connected. By using the digital limits
(DES) the additional functions of the switching
contact are available.
Otherwise this mode can be left in 'no function'.