Citrix NetScaler SDX 8015 Manual page 230

Hide thumbs Also See for NetScaler SDX 8015:
Table of Contents

Advertisement

To verif y proper operation of the MPX appliance's components
1. Access the console port and enter the administrator credentials.
2. Run the following command from the command line interface of the appliance to display the serial number: show
hardware
T he serial number might be helpful in the event that you want to contact Citrix Technical Support.
Example
> show hardware
Platform: NSMPX-11500 12*CPU+8*IX+4*E1K+2*E1K+2*CVM N3 1400210
Manufactured on: 8/12/2014
CPU: 2400MHZ
Host Id: 872841350
Serial no: 2NSHJ2DR9E
Encoded serial no: 2NSHJ2DR9E
Done
3. Run the following command to display the status of the active 1G and 10G interfaces: show interf ace
4. In the show interface command's output, verify that all of the interfaces are enabled and the status of every interface
is shown as UP/UP.
Note: If you do not have an SFP+ transceiver for every port, verify the interfaces in stages. After checking the first set
of interfaces, unplug the SFP+ transceivers and plug them in to the next set of ports. T he SFP+ transceivers are not hot-
swappable. T herefore, restart the MPX appliance after you connect the transceivers.
5. Run the following commands for each of the interfaces that are not in the UP/UP state:
enable interf ace 1/x
enable interf ace 10/x
where x is the new interface number.
6. Run the following command to verify that the status of the power supplies is normal: stat system -detail
Example
> stat system -detail
NetScaler Executive View
https://docs.citrix.com
© 1999-2017 Citrix Systems, Inc. All rights reserved.