Download Print this page

Parts List; Troubleshooting And Maintenance - Elkay SWIRLFLO Series Installation, Care & Use Manual

Fountains with flexi-guard

Advertisement

EDFPB117C, EDFPBM117C, EDFPB117RAC, EDFPBM117RAC, EDFPBV117C,
EDFPBMV117C, EDFPBV117RAC, EBFPBMV117RAC

PARTS LIST

ITEM NO.
PART NO.
1
56073C
Bubbler Assy
2
40319C
Fitting - Orifice
3
50171C
O-Ring
4
50314C
Orifice - Flow Straightener
5
56011C
Housing Assembly
6
55997C
Pedestal
7
75580C
Bubbler Locknut
8
98118C
Bubbler Assembly VR
9
100322740560
Gasket - Black .68 x 1.03 VR
10
15009C
Nipple - Bubbler VR
11
28474C
Basin - Swirlflow
12
28473C
Lower Shell
13
45767C
Fountain Body
14
28343C
Cover Plate
15
45781C
Sleeve
16
45847C
Pin - Push Button
17
45848C
Push Button
18
50986C
Holder - Regulator
19
61313C
Regulator
20
15005C
Retaining Nut
21
56163C
Gasket - Drain
22
45769C
Assy - Drain/Tailpipe
23
45768C
Drain - Plug 1-1/2"
24
56092C
Poly Tubing (Cut To Length)
25
28392C
Back Panel RH ADA
28393C
Back Panel LH ADA
26
55000966
AP-99 Panel (Optional)
27
111008343890
Screw - #10-24 x .62 HHMS
28
70432C
Screw - #8-32 x .38 THSM
29
38417001
Screw - #8-18 x .37 HHSM
30
75560C
Screw - 5/16-18 x 1.00 HHMS
31
75632C
Setscrew - #10-32 x .31
32
70817C
Fttng - Elbow 1/4 x 1/4
33
55996C
Strainer
34
75671C
Spring - Push Button
33
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
1/4" O.D. TUBE
COLD WATER SUPPLY
WATER INLET
TO COOLER
NOTE: WATER FLOW
DIRECTION
Figure 12 – Water Supply Connections
PRINTED IN U.S.A.
www.DrinkingFountainDoctor.com
TROUBLESHOOTING & MAINTENANCE
DESCRIPTION
orifice can cause water flow to spurt or not
regulate. Mineral deposits may be removed
from the orifice by poking with a small round
file not over 1/8" diameter, or using a small
diameter wire
regulate flow as in Step 8 of the installation
instructions. If replacement is necessary, see
parts list for correct regulator part number.
Fittings: Cooler is provided with lead-free
connectors which utilize an o-ring water seal.
To remove tubing from the fitting, relieve water
pressure, push in on the gray collar while
pulling on the tubing. (See Figure 11) To insert
tubing, push tube straight into fitting until it
reaches a positive stop (approximately 3/4")
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
Page 7
Orifice Assembly: Mineral deposits on
.
!
CAUTION:
DO NOT file or cut orifice
material.
Stream Regulator: If orifice is clean,
Actuation of Quick Connect Water
Figure 11 – Quick Connect Fittings
800-518-5388
.
97922C (Rev. E - 3/05)

Advertisement