Recommendations on network security
● Use the configuration options of the interfaces, e.g. the "Edge Type".
● Configure the receive ports so that they discard all untagged frames ("Tagged Frames
Only").
Available protocols
The following list provides you with an overview of the open protocol ports.
The table includes the following columns:
● Protocol
● Port
● Default port status
– Open
– Closed
● Configurable port
– ✓
– --
● Authentication
Specifies whether the communication partner is authenticated.
● Encryption
Specifies whether or not the transfer is encrypted.
Protocol
Protocol/
Port number
TELNET
TCP/23
SSH
TCP/22
HTTP
TCP/80
HTTPS
TCP/443
SNMP
UDP/161
SNTP
UDP/123
NTP
PROFINET
UDP/34964,
UDP/49154,
49155
16
The factory setting of the port is "Open".
The factory setting of the port is "Closed".
The port status can be changed.
The port status cannot be changed.
Default port status
Open
Open
Open
Open
Open
Closed
Open
Configurable port
Authentication
--
Yes
--
Yes
--
Yes
Yes
Yes
No
--
No
Operating Instructions, 09/2018, C79000-G8976-C306-08
Encryption
No
Yes
No
Yes
Yes (when
configured)
No
No