schmersal AZM 161 Series Operating Instructions Manual

schmersal AZM 161 Series Operating Instructions Manual

Solenoid interlock

Advertisement

Quick Links

Operating instructions
Solenoid interlock
Operating instructions. . . . . . . . . . . . .pages 1 to 6
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .4
4.2 Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5
5.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of improper use or manipulation of the safety
switchgear, personal hazards or damages to machinery
or plant components cannot be excluded. The relevant
requirements of the standard ISO 14119 must be observed.
EN
AZM 161../..
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZM 161 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal AZM 161 Series

  • Page 1: Table Of Contents

    2.4 Technical data .........3 Further technical information can be found in the Schmersal 2.5 Safety classification of the interlocking function.
  • Page 2: Exclusion Of Liability

    Operating instructions Solenoid interlock AZM 161../.. 1.7 Exclusion of liability Manual release We shall accept no liability for damages and malfunctions resulting from (for set-up, maintenance, etc.) defective mounting or failure to comply with this operating instructions Manual release is realised by turning the triangular key by 180° (M5 manual.
  • Page 3: Technical Data

    Operating instructions Solenoid interlock AZM 161../.. 2.5 Safety classification of the interlocking function The entire concept of the control system, in which the safety component is integrated, must be validated to the Standards: ISO 13849-1 relevant standards. Envisaged structure: - Basically: applicable up to Cat.
  • Page 4: Mounting

    Operating instructions Solenoid interlock AZM 161../.. 3. Mounting 4. Electrical connection 3.1 General mounting instructions 4.1 General information for electrical connection Three mounting holes are provided for fixing the enclosure. The solenoid interlock is double insulated. The use of an earth wire is not The electrical connection may only be carried out by authorised.
  • Page 5: Set-Up And Maintenance

    Operating instructions Solenoid interlock AZM 161../.. AZM 161ST-../.. with connector AZM 161SK-12/03...G AZM 161CC-12/03...G AZM 161ST-12/11... AZM 161ST-11/12... +24 VDC 71 72 71 72 14 21 22 41 42 51 52 63 64 A1 A2 14 21 22 41 42 51 52 63 64 A1 A2 1 2 3 4 1 2 3 4...
  • Page 6: Eu Declaration Of Conformity

    Solenoid interlock AZM 161../.. 7. EU declaration of conformity EU declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.