Failure to follow the instructions found in this manual may result in damage to the product described in this manual, or other components of the system. The procedure set forth in this manual shall only be performed by persons qualified to service electronic equipment. Contents and specifications within this manual are given without warranty, and are subject to change without notice. RTD Embedded Technologies, Inc. shall not be liable for errors or omissions in this manual, or for any loss, damage, or injury in connection with the use of this manual.
Page 5
Performing a Firmware Upgrade .............................. 59 6.18.1 Using the Web GUI 6.18.2 Using ICLI 6.18.3 Using USB Serial Console Troubleshooting Additional Information PC/104 Specifications ................................62 PCI and PCI Express Specification ............................62 | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Page 6
Figure 41: PuTTY session logging to facilitate automatic configuration backup ....................57 Figure 42: Configuration backup using TFTP via ICLI ............................57 Figure 43: Configuration backup using Web GUI ..............................57 Figure 44: Factory default configuration using Web GUI............................58 | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Page 7
Table 19: IDAN-LAN35Mx08HR-D, Rear Connector Pin Out..........................33 Table 20: RJ-45 Signal Descriptions ..................................34 Table 21: Link Status LEDs ....................................38 Table 22: Switch Status LED ....................................38 | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
DIL connectors or in IDAN frames with either RJ-45 or 37-pin “D” connectors. The LAN35Mx08 features the RTD StackNET® connector, which allows additional RTD Ethernet switches and routers to be stacked in a PCIe/104 system with direct board-to-board Ethernet connectivity. The LAN35MH08HR is intended to be the host of a StackNET® stack and features a PCI Express Gigabit Ethernet controller for connection to a PCIe/104 cpuModule.
Intel i210 PCI Express Ethernet Controller for interface to host cpuModule Eight 1000/100/10 Mbps Ethernet ports One upward StackNET® port for stacking switch expansion Power connector for standalone applications or use with RTD’s PCIe/104 or PCI/104-Express power supplies. • LAN35ME08HR expansion switch...
PTIONS RTD’s line of PCIe/104 Gigabit Ethernet Switches are available with RJ-45 or 10-pin DIL connectors. The LAN35MH08HR “host” version may be used as a stand-alone device, and include a power connector, while the LAN35ME08HR “expansion” version must be used with a host. The LAN35MH08HR &...
XK-CM83 DIL connector to RJ-45 (includes one adapter cable) Cable kit for all LAN35Mx08HR boards to provide a Mini USB Type B XK-CM123 connection to the USB Serial Console | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
The Intelligent Data Acquisition Node (IDAN®) building block can be used in just about any combination with other IDAN building blocks to create a simple but rugged 104™ stack. This module can also be incorporated in a custom-built RTD HiDAN® or HiDANplus® High Reliability Intelligent Data Acquisition Node.
PCIe/104 Bus (CN1 and CN2) Differential Output Voltage DC Differential TX 95.2 116.9 Ω Impedance Differential Input 0.175 Voltage DC Differential RX 92.7 115.8 Ω Impedance Electrical Idle Detect Threshold | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Page 14
Output low voltage = 12 mA Output low voltage = 2 mA Input high voltage 1.85 Input low voltage -0.3 Input high current μA Input low current μA Input capacitance | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
When removing it from the bag, hold the board at the edges, and do not touch the components or connectors. Handle the board in an antistatic environment, and use a grounded workbench for testing and handling of your hardware. Physical Characteristics STEP model is available upon request; contact RTD Tech Support for more information. • LAN35Mx08HR-D Weight: Approximately 91 g (0.20 lbs) – with heatsink •...
Power (LAN35MH08HR only) 1x12, 0.1”, right angle FCI 65039-025LF CN24 Factory Use Only CN25 Factory Use Only CN26 External LED Signals, Reset 2x13, 2mm, vertical FCI 89947-726LF Button, Time Tick | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Receive - MDI_C+ Not Used MDI_C- Not Used MDI_A+ Transmit + MDI_A- Transmit - MDI_D+ Not Used MDI_D- Not Used Shield Ground Shield Ground Table 8: Ethernet DIL Signal Descriptions | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Interface (ICLI). CN19 is a USB “device” port, with an Exar XR21B1411IL16 USB UART device. It is intended to be connected to the USB port of a PC (RTD cpuModule, laptop, or desktop). The USB signals comply with the USB 2.0 specification (Full Speed, 12Mbit/sec).
CN23 may be used to power just a single LAN35MH08HR, or it may be used to power a stack of multiple RTD StackNET boards (e.g. one LAN35MH08HR plus several LAN35ME08HR boards). Additional power input options are any of RTD’s...
CN23! If two +5V power supplies conflict, all boards in the stack may be damaged or destroyed. If a stack powered by CN23 contains any boards other than an RTD StackNET product (not recommended), be sure the non-StackNET board(s) do not back feed +5V onto the bus before applying power.
Refer to section 4.5 for details on the serial port connection. b. Configure the CEServices software via the ICLI (see the software configuration information later in this document for details). | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
IDAN-LAN35Mx08HR-D Weight: Approximately 310 g (0.68 lbs) • Dimensions: 152 mm L x 130 mm W x 17 mm H (5.983 in L x 5.117 in W x 0.669 in H) Figure 13: IDAN-LAN35Mx08HR-D Dimensions | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Dimensions: 152 mm L x 130 mm W x 17 mm H (5.983 in L x 5.117 in W x 0.669 in H) Figure 14: IDAN-LAN35Mx08HR-RJ Dimensions Figure 15: IDAN-LAN35MH08HR-RJ Figure 16: IDAN-LAN35ME08HR-RJ | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
IDAN-LAN35Mx08HR-D Connectors The IDAN-LAN35MH08HR-D and IDAN-LAN35ME08HR-D both feature rugged 37-pin “D” connectors which each connect to four of the onboard Ethernet ports. These connectors can easily be adapted to RJ-45 connections by using RTD cable kit IDAN-XKCM48. LAN35MH08HR or IDAN...
No Connect No Connect No Connect Table 19: IDAN-LAN35Mx08HR-D, Rear Connector Pin Out IDAN-LAN35Mx08HR-D LEDs Due to space limitations on the frame the IDAN-LAN35Mx08HR-D does not bring out any LEDs. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Red Flashing – Error • HST or DWN – Host or StackNet down link Green – Link at 1Gbps, flash with activity Yellow – Link at 10/100Mbps, flash with activity | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Refer to section 4.5 for details on the serial port connection. Configure the CEServices software via the Command Line Interface (see the software configuration information later in this document for details). Figure 27: Example IDAN System | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
The Figures below shows the functional block diagram of the LAN35MH08HR and LAN35ME08HR. The key features of the board are discussed in the following sections. Figure 28: LAN35MH08HR Block Diagram | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
To use the I210, the appropriate networking drivers must be loaded in your Operating System. The I210 is a common Ethernet controller, so it is supported by many OSes. RTD distributes the Intel PRO Ethernet drivers for Windows 7 and later. For Linux, support is built into kernel 3.5 or later using the igb driver.
PC. Modern versions of Windows include drivers for the USB UART. For older versions of Windows, a driver is provided by RTD. Once USB is connected and the drivers are loaded, the console interface will appear as a serial COM port in the PC’s operating system (e.g. COM5). The COM port number can vary depending on how ports were enumerated by the operating system, so it is difficult to predict.
Black text indicates user typed text. Text in enclosed in <> indicate a specific keyboard key such as the spacebar indicated by <Space> or the enter key indicated by <Enter>. Press ENTER to get started If you require support, please contact RTD Embedded Technologies, Inc. Username: admin<Enter>...
However, any network communication with the CPU board would be interrupted while the CPU reboots (including Intel I210 Ethernet controller on the LAN35MH08HR). A “cold” reset which interrupts power to the LAN35MHx08 (RSM reset, ACPI S3 standby, etc) will reset the VSC7428. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
<Enter>. The default password is blank, so just press <Enter>. Press ENTER to get started If you require support, please contact RTD Embedded Technologies, Inc. Username: admin<Enter>...
Once in configuration mode, the command prompt changes from HOSTNAME# to HOSTNAME(config)#. In the factory default configuration with no host name set, the prompt will simply be (config)#. configure terminal<Enter> (config)# ?<Enter> | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Page 43
Managed Switch Firmware package. When done configuring the switch, use exit to exit configuration mode. Multiple uses of exit will bring you to the exec level, or you can use end to bring you directly back to the exec level. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
RTD-SWITCH# show running-config<Enter> Building configuration... banner exec "TIP: If Backspace does not work, use Ctrl-H for Backspace." banner login "If you require support, please contact RTD Embedded Technologies, Inc." hostname RTD-SWITCH logging level notice username admin privilege 15 password none...
Page 45
SSH network connection -- more --, next page: Space, continue: g, quit: ^C <Space> line vty 5 exec-timeout 15 0 location SSH network connection line vty 6 exec-timeout 15 0 | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Once in the interface configuration sub- mode, the command prompt changes from HOSTNAME(config)# to HOSTNAME(config-if)#. To switch back to “global” configuration mode, type exit. configure terminal<Enter> (config)# interface GigabitEthernet 1/1<Enter> | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Page 48
To set an IP address, one should create a VLAN interface and set an IP address there, then assign one or more physical interfaces to the newly- created VLAN. By default, all ports are part of VLAN 1, which already exists in factory default configuration. Refer to the following sections for details. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
(note the last line): show running-config<Enter> Building configuration... banner exec "TIP: If Backspace does not work, use Ctrl-H for Backspace." banner login "If you require support, please contact RTD Embedded Technologies, Inc." logging level notice username admin privilege 15 password encrypted TXVzdEJlQ2hhbmdlZA== The above commands demonstrate the most basic method of setting a password.
(8.8.8.8 and 8.8.4.4). DHCP lease time is 1 day. To be a DHCP server, the switch must be configured with a static IP address. In this case, we use the same static IP address as before (192.168.0.5). configure terminal<Enter> | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Subnet Mask: 255.255.255.0 Default Gateway: 192.168.0.1 6.11 Enabling SNMP server SNMP is disabled by default by RTD Embedded Technologies. SNMP can be enabled by performing the following command via ICLI: configure terminal<Enter> (config)# snmp-server<Enter> (config)# exit<Enter> To verify that SNMP has been enabled, run the show snmp command and look at the first line of the configuration shown.
Login using the same username and password as you would for the USB Serial Console. Once you are logged in, the ICLI interface behaves identical to the USB Serial Console. Figure 31: Connecting with PuTTY (click Open to connect) | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
SSH access is enabled in the factory default configuration. It may be disabled with the configuration command no ip ssh. To re-enable it, use the configuration command ip ssh. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
You will be prompted to login. Use the same username and password as you would for the USB Serial Console or SSH. The appearance of the login prompt may vary depending on your web browser. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Similar to ICLI, one must remember to save their configuration changes to the flash, or they will be lost when the switch is rebooted. Under the Web GUI, the configuration may be saved under Maintenance > Configuration > Save startup-config. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
PuTTY and other terminal emulators include a session logging feature which automatically saves the session contents to a text file. This allows for automatic backups of a configuration. Every time show running-config is run, it is automatically captured to the log, where it may be extracted later. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Under ICLI, the factory defaults may be loaded by deleting the startup configuration from the flash, and then rebooting CEServices. This may be done via either USB Serial Console, SSH, or Telnet. Once the startup configuration is deleted, a few errors may appear on the console | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Performing a Firmware Upgrade From time to time, RTD may offer firmware upgrades for the LAN35Mx08. These upgrades may be installed by the user. Running the latest available firmware is highly recommended. Running an older firmware version may have security implications.
User-installed firmware upgrades will not affect the RedBoot boot loader. This is by design. The boot loader provides low level system recovery and troubleshooting. In general, the boot loader should not be altered unless you have been given special instructions from RTD Techsupport.
If problems persist, or you have questions about configuring this product, contact RTD Embedded Technologies via the following methods: Phone: +1-814-234-8087 E-Mail: techsupport@rtd.com Be sure to check the RTD web site (http://www.rtd.com) frequently for product updates, including newer versions of the board manual and application software. | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
PCI and PCI Express Specification A copy of the latest PCI and PCI Express specifications can be found on the webpage for the PCI Special Interest Group: www.pcisig.com | www.rtd.com LAN35MH08HR & LAN35ME08HR User’s Manual RTD Embedded Technologies, Inc.
Page 63
During the one year warranty period, RTD Embedded Technologies will repair or replace, at its option, any defective products or parts at no additional charge, provided that the product is returned, shipping prepaid, to RTD Embedded Technologies. All replaced parts and products become the property of RTD Embedded Technologies.
Page 64
RTD Embedded Technologies, Inc. 103 Innovation Boulevard State College, PA 16803 USA Telephone: 814-234-8087 Fax: 814-234-5218 www.rtd.com sales@rtd.com techsupport@rtd.com Copyright 2019 by RTD Embedded Technologies, Inc. All rights reserved.
Need help?
Do you have a question about the LAN35M 08 Series and is the answer not in the manual?
Questions and answers