Convertible facepiece.
for air purifying respirator (apr), continuous flow supplied air respirator
(cf–sar), and powered air purifying respirator (papr) configurations (40 pages)
• SPERIAN cannot predict what will happen to this respirator in every potential environment. Materials can be chemically attacked if exposed to the wrong environment and may exhibit excessive corrosion or other forms of damage.
Page 3
• Use of components other than those listed on the NIOSH approval label and in this manual, or as authorized by SPERIAN, or modification of this respirator in any manner will void the NIOSH certification and invalidates all SPERIAN’s warranties for the respirator.
Page 4
• Users must clean and maintain this respirator only in accordance with SPERIAN’s instructions. • Before entering a hazardous environment while wearing this respirator, you must conduct safe, scientific tests to determine if the environment could render the equipment unsafe.
Page 5
• Following is a list of contaminants for which these respirators must not be used. This list is far from complete. Please contact SPERIAN for information on other contaminants. • FAILURE TO COMPLY WITH THESE WARNINGS MAY RESULT IN PERSONAL INJURY, ILLNESS, OR DEATH.
Page 6
WARNING Filters improperly used or improperly assembled to the facepiece could cause leakage, which could lead to personal injury, illness, or death. 2. Mercury Vapor Cartridges Special or Critical User’s Instructions: The mercury vapor cartridges incorporate 4 (four) end-of-service-life indicators (ESLIs). Each ESLI, yellow in color when new, turns to gray when exposed to mercury vapor.
Page 7
B. HOW TO DON THE RESPIRATOR WARNING Always read cartridge labels prior to use to be certain that you have cartridges and/or filters that will provide the required protection. Filters labeled for protection against particulates only shall not be used for gases/vapors, and cartridges labeled for protection against gases/vapors only shall not be used for particulates.
Page 8
Alternatively, the cartridges may be removed to perform the fit check. If removed, SPERIAN recommends someone other than yourself reinstall them after a leak-tight fit is achieved. It is difficult for...
If you wait too long to replace the cartridges, particulates may leak past the face seal instead of being collected on the filter; therefore, SPERIAN recommends that the cartridges be changed at least daily.
Page 10
Replace the cartridges earlier if you detect the contaminant by smell, taste, or irritation, or if either cartridge shows any signs of damage. SPERIAN recommends cartridges be replaced daily even if the end-of- service-life indicator has not changed color, or the change-out schedule is de- termined to be greater than 1 day.
Page 11
In addition, when an R-series filter is used in an oil-containing atmosphere, the filter must be replaced after each 8-hour work shift. SPERIAN recommends, due to considerations of hygiene, that all filters be replaced at least daily, and more often if necessary.
Page 12
G. INSPECTION Inspect this respirator for defects as described below before and after each use and at least monthly if not used. Repair as necessary, clean and disinfect after each use, and store properly to assure that the respirator is maintained in satis- factory working condition.
H. MAINTENANCE Respirators should be cleaned after each day’s use by washing with mild soap and warm water. Then disinfect the respirators with a suitable sanitizing solution. ANSI Z88.2, latest edition, also provides information and guidelines on the cleaning and sanitizing of respirators.
Page 14
7) Test the new valve by performing a negative pressure fit check as described in section C. I. STORAGE WARNING This SPERIAN respirator does not have a defined storage life. Carefully inspect the respirator before each use. Failure to comply with this warn- ing may lead to personal injury, illness, or death. CAUTION The maximum storage temperature for the respirator is 140°F (60°C).
K. ADDITIONAL INFORMATION If you need assistance or additional information on any SPERIAN product, consult your local distributor or contact: SPERIAN 3001 S. Susan Street Santa Ana, CA 92704 U.S.A. (714) 545-0410 or (888) APR-SCBA FAX (714) 850-0299 L. REPLACEMENT PARTS...
Page 16
CARTRIDGE AND FILTER TABLE (See Figure on page 17) ITEM MODEL FILTERS 1060 Filter Pad, N95 1070 Filter Pad, N99/R95 1050 P100, Micro 1190 P100 Slimline 1195 P100 Disk ITEM MODEL CARTRIDGES 100100 Organic Vapors 100200 Acid Gases 100300 Organic Vapors and Acid Gases 100400 Ammonia and Methlyamine 100600...
LIMITATION OF LIABILITY: No other oral warranties, representations, or guaran- tees of any kind have been made by SPERIAN, its distributors, or the agents of ei- ther of them, that in any way alter the terms of this warranty. EXCEPT AS HEREIN...