Technical Specifications

Attribute
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold)
IEC 60068-2-2 (Test Bd, Operating Dry Heat)
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
Temperature, surrounding air, max
Voltage and current ratings, max
Power consumption, max
Power dissipation, max
Isolation voltage
Wire size
Wiring category
Enclosure type rating
North American temp code
ATEX temp code
IECE x temp code

Additional Resources

These documents contain additional information concerning related products from Rockwell Automation.
Resource
ControlNet Modular Repeater Adapter Installation Instructions, publication
ControlNet Modular Repeater Short-distance Fiber Module Installation Instructions, publication
ControlNet Modular Repeater Medium-distance Fiber Module Installation Instructions, publication
ControlNet Fiber Ring Modules Installation Instructions, publication
ControlNet Modular Repeater Dual Copper Module Installation Instructions, publication
ControlNet Fiber Media Planning and Installation Guide, publication
ControlNet Coax Media Planning and Installation Guide, publication
Industrial Automation Wiring and Grounding Guidelines, publication
Product Certifications website,
http://www.rockwellautomation.com/products/certification
You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative.
Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.
Allen-Bradley and Rockwell Automation are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 1786-PC001B-EN-P - January 2015
Supersedes 1786-PC001A-EN-P - September 2014
1786-RPA/B
1786-RPCD
0...60 °C (32...140 °F)
60 °C (140 °F)
Input: 700 mA @ 24V DC, SELV
Backplane: 400 mA @ 5V DC
Output: 1.6 A @ 5V DC
16.8 W
2 W
8.8 W
2 W
N/A (SELV), functional insulation
N/A (SELV), functional insulation
type, ContolNet to system
type, ContolNet to system and
between ControlNet channels
2
NA
0.21...3.3 mm
(24...12 AWG)
solid or stranded copper wire rated
at 105 °C (221 °F) or greater, 1.2
mm (3/64 in.) insulation max for
power connections
2 - on power ports
2 - on ControlNet ports
2 - on ControlNet ports
None (open-style)
T5
T5
T5
T5
T5
T5
1786-IN013
1786-IN012
1786-IN011
1786-IN003
1786-IN001
CNET-IN001
CNET-IN002
1770-4.1
1786-RPFM
1786-RPFS
Backplane: 400 mA @ 5V DC
Backplane: 300 mA @ 5V DC
2 W
1.5 W
2 W
1.5 W
T5
T5
T5
T5
T5
T5
Description
Installation instructions for 1786-RPA modular repeater adapters.
Installation instructions for 1786-RPFS repeater modules, short-distance fiber.
Installation instructions for 1786-RPFM repeater modules, medium-distance fiber.
Installation instructions for 1786-RPFRL and 1786-RPFRXL repeater modules, fiber ring
Installation instructions for 1786-RPCD repeater modules,dual copper.
Information about installing a ControlNet fiber media system.
Information about installing a ControlNet coaxial media system.
General guidelines for installing a Rockwell Automation® industrial system.
Declarations of conformity, certificates, and other certification details.
1786-RPFRL/B, 1786-RPFRXL/B
Input: 570 mA @ 5V DC
Relay: 900 mA @ 30V DC, Class 2,
resistive only
2.8 W
2.8 W
50V (continuous), basic insulation
type, relay contacts to system
0.25...2.5 mm
solid or stranded copper wire rated
at 75 °C (167 °F) or greater, 1.2 mm
(3/64 in.) insulation max for power
connections
2 - on relay ports
T4A
Copyright © 2015 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
2
(22...14 AWG)
PN-254949

Advertisement

loading

This manual is also suitable for:

1786-rpcd1786-rpfs1786-rpfm1756-rpfrl1786-rpfrxl