Siting and levelling the boiler
!
Please note
Damage to the flue outlet can result in leaks.
Never lift or move the boiler by the flue outlet.
Fig.2
1. Screw the adjustable feet into the base rails. The
adjustable feet are in the same bag as the type
plate.
Note
If a neutralising system is being fitted, wind out the
adjustable feet as far as possible.
Note
A suitable condensate drain (maximum 50 mm above
floor level) must be available in the installation room if
the boiler is installed at ground level.
2.
1.
2.
±15
2. Using the adjustable feet, position the boiler so it
rises slightly towards the back (max. 5 mm over the
boiler length). No special foundations are required.
5