WARNINGS AND CAUTIONS:

TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH ELECTRICAL CODES AND REGULATIONS.
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN.
DO NOT GANG VERTICALLY.
ONLY INSTALL FOR THE ALLOWED LOAD TYPES. INSTALLATION FOR ANY OTHER LOAD TYPE WILL VOID WARRANTY AND POSSIBLY CAUSE DAMAGE TO
THIS DEVICE AND/OR CONNECTED EQUIPMENT.
USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY.
INSTALL THIS DEVICE IN A METAL OUTLET BOX ONLY.
INPUT - 120 - 277
VAC 60 HZ

Features and Operation:

Installation Requirements:

Installation Instructions:

TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER AT
WARNING:
1.
CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE
WIRING!
2.
3.
4.
5.
6.
7.
FAN SPEED CONTROLS
Cat. Nos. AWRMG-QXX, AWSMG-QXX & AWSMT-QXX
Figure 1.
not
(See Figure 2).
(see Figure 3).
Installation is complete.

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

RENOIR II
INSTALLATION
Load
Disconnected
Hot (Black)
Black
Yellow
White
Neutral (White)
Black
Hot (Black)
Yellow
White
Neutral (White)
Fan Speed Control
Hot (Black)
White
Line
120-277VAC
60 Hz
Neutral (White)
Load
Load
Connected
Disconnected
Service Switch
Blue
Green
Ground
– Run a separate neutral wire
for each control circuit
Blue
Green
Ground
– Run a separate neutral wire
for each control circuit
Center tab in opening
Align flats when
installing knob
Wiring Diagram
Blue
Yellow
For u e in multi-way
control (remote)
application .
Cap wire if not u ed.
Ground (Green)
Load
Connected
Service Switch
Load
White
Load
White
Black
Fan
White

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RENOIR II Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Leviton RENOIR II Series

  • Page 1 RENOIR II FAN SPEED CONTROLS Cat. Nos. AWRMG-QXX, AWSMG-QXX & AWSMT-QXX INSTALLATION WARNINGS AND CAUTIONS: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING! TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH ELECTRICAL CODES AND REGULATIONS. IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN.
  • Page 2 Multi-Gang Installations: NOTE: TEST FIT DEVICE INSTALLATION WITH THE WALL PLATE PRIOR TO BREAKING FINS OR INSTALLING DEVICES TO ENSURE YOU UNDERSTAND ALL Narrow/Narrow REQUIREMENTS. De-ratings: Joiner Bar Joiner Bar Fan Speed Controls 0 fins 1 fin 2 fins Full variable, full quiet removed removed removed...

Table of Contents