Trouble Condition
Visual Indications
Low battery
Fault Mode
end of Unit Life
end of Unit Life Hush
Mode (after push/
release test/Hush
button during end
of Life)
network error
network error Hush
(after button push
during network
error)
If you require further information please contact Product Support at 1-800-880-6788 or write us at:
Kidde Canada Inc., P.O. Box 40, Apsley, ON K0L 1A0. Our internet address is www.kiddecanada.com.
Audible Indications
Chirp every 60 sec, voice every
30 sec: "Replace alarm."
Voice stops after 5 mins.
Chirp every 30 sec.
Voice every 30 sec: "Error, see
trouble shooting guide"
After 5 mins: no voice message
Double chirp every 30 sec.
First 5 mins: Voice every 30 sec:
"Replace alarm, press button to
temporarily silence." Voice stops
Amber
after 5 mins. After 7 days: Chirps
continue. Voice every 30 sec for
5 mins: "Replace alarm."
LED
Voice "Temporarily Silenced."
blinks
End of Unit Life chirps silenced
for 24 hrs. (7 days after End of
Unit Life chirps begin, the chirps
every
cannot be silenced.)
5 seconds
Chime every 30 secs. Voice every
30 sec: "Connection lost. Press
button to temporarily silence."
After 5 min: no voice messages
(Note: network must have 3 or
more alarms for voice messages.)
Voice "Temporarily
Silenced."
Action:
* Remove, discharge, dispose unit, and replace as
soon as possible.
* See Cleaning Your Alarm section.
* Push Test/Hush button once to attempt to
reset the unit .
* Red LED will blink out an error code (number of
blinks) when Test/Hush button is push/released
once. Report the number of blinks to customer
service if needed.
* Push/release Test/Hush button to temporarily
silence (see End of Unit Life Hush Mode section
below)
* Remove, discharge, dispose unit, and replace as
soon as possible.
* Remove, discharge, dispose unit, and replace as
soon as possible.
* Push/release the Test/Hush button once to
silence for 24 hrs at a time.
* Red LED will blink out an error code (number of
blinks) when Test/Hush button is push/released
once. Report the number of blinks to customer
service if needed.
* Push and hold Test/Hush button until two beeps
are heard (approx 4 sec) and then release the
button to try to rejoin. Or reset (section 9.3) and
then rejoin (section 9.2).
* If error persists, remove, discharge, and replace
alarm as soon as possible.