SOLAR INLET AND OUTLET
All pipe work must be cleared of foreign matter before connection and purged before attempting to operate the
water heater. All olive compression fittings must use brass or copper olives. Use an approved thread sealant
such as Teflon tape on all sealing threads.
The solar cold outlet and solar hot inlet connections are located at the top of the solar storage tank.
Notes:
It is important not to cross connect the solar hot and solar cold pipes to the incorrect connections.
The solar cold pipe connects to the bottom of the solar collectors and the solar hot pipe connects to
the top of the solar collectors on the opposite side to both the solar cold pipe connection and the hot
sensor connection.
The solar hot inlet connection is located in the centre of the top of the solar storage tank (the
connection is marked by a label on top of the storage tank).
The solar cold outlet connection is located at a corner of the top of the solar storage tank (the
connection is marked by a label on top of the storage tank).
Connect the solar pipes to the solar storage tank using only the fittings supplied.
To connect the solar hot and solar cold pipes to the solar storage tank:
Solar hot pipe connection
Remove the plastic cap from the solar hot inlet pipe end at the top of the solar storage tank.
Undo the compression nut and olive from the compression union and fit over the solar hot pipe connection.
Fit the ½" x ½" nipple from the compression
union supplied to the solar hot inlet pipe end.
Connect the solar hot pipe (flow from the
collector) to the ½" x ½" nipple using the
compression nut and olive supplied.
Solar cold pipe connection
Remove the plastic cap from the solar cold
outlet pipe end at the top of the solar storage
tank.
Undo the compression nut and olive from the
compression union and fit over the solar cold
pipe connection.
Fit the ½" x ½" nipple from the compression
union supplied to the solar cold outlet pipe
end.
Connect the solar cold pipe (flow to the collector) to the ½" x ½" nipple using the compression nut and
olive supplied.
SOLAR
HOT PIPE
CONNECTION
PRESSURE
RELIEF
VALVE
PLASTIC CAP
(REMOVE &
DISCARD)
CONNECTION
SOLAR COLD & SOLAR HOT CONNECTIONS
SOLAR DRAIN BACK STORAGE TANK - 160
43
CONNECTIONS – PLUMBING
COMPRESSION
UNION
SOLAR
COLD PIPE
SK6569