• E 1793 01 1
Guard Unit Central Programming
Jumpers CN5 ,CN6 and CN7: short circuit 1 and 2
Jumper CN8: short circuit 2 and 3
Installation Features
-
Use the CITYCOM Guard Unit Central "Buzzer Call" version.
-
Press door release button to call guard unit from house.
-
NO call signalling or retention in Guard Unit Central.
-
NO secret mode in any of the 4 communication types.
-
NO possibility of including guard unit pushbutton in outdoor panel.
INSTALLATION DIAGRAMS
CITYCOM CENTRAL UNIT IN DAY MODE
CITYMAX BUZZER CALL TELEPHONES
FERMAX ELECTRÓNICA S. A. E.
CITYCOM III Guard Unit Central
8
Code 94487 V-02/04