Burley LONGITUDE Installation, Servicing & User Instructions

Flueless gas heater

Advertisement

Quick Links

LONGITUDE
G4530 – G4539 MODELS
FLUELESS GAS HEATER
INSTALLATION, SERVICING
& USER INSTRUCTIONS
FOR USE IN THE COUNTRIES STATED ON THE DATA PLATE AND CARTON
WITH NATURAL GAS G20 & LPG G31
(REFER TO RATING LABEL)
For the following countries: GB, IE
EVEN IF YOU HAVE FITTED THESE FIRES BEFORE,
PLEASE FOLLOW THESE INSTRUCTIONS STEP BY STEP.
Legislation and regulations do change over time!
This product is not suitable for primary heating purposes.
LEAVE THESE INSTRUCTIONS WITH THE USER
TO OBTAIN YOUR FIRST YEAR GUARANTEE, THE INSTALLER AND CUSTOMER
MUST FILL IN THE SEPARATE GUARANTEE AND RETURN IT TO
BURLEY WITHIN 7 DAYS OF FITTING.
A FREE SECOND YEAR GUARANTEE IS ALSO OFFERED BUT THIS IS SUBJECT TO THE FIRE BEING
SERVICED BY A GAS SAFE ™ REGISTERED INSTALLER (FORMERLY CORGI) DURING THE FIRST
YEAR OF OWNERSHIP. PROOF OF SERVICING MUST BE RETAINED
FAILURE TO HAVE THIS APPLIANCE FITTED BY GAS SAFE™ REGISTERED INSTALLER (FORMERLY
CORGI) FITTER INVALIDATES THE WARRANTY
Burley Appliances Ltd,
Lands End Way, Oakham, Rutland, LE15 6RB
Telephone: +44 (0)1572 756956 Fax: +44 (0)1572 724390
e-mail:
info@burley.co.uk
web:
www.burley.co.uk
G4530-39InstUser
G20 / G31
March 2019

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LONGITUDE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Burley LONGITUDE

  • Page 1 TO OBTAIN YOUR FIRST YEAR GUARANTEE, THE INSTALLER AND CUSTOMER MUST FILL IN THE SEPARATE GUARANTEE AND RETURN IT TO BURLEY WITHIN 7 DAYS OF FITTING. A FREE SECOND YEAR GUARANTEE IS ALSO OFFERED BUT THIS IS SUBJECT TO THE FIRE BEING SERVICED BY A GAS SAFE ™...
  • Page 2: Technical Data

    INTRODUCTION Thank you for choosing this Burley product. All of our products carry a CE mark which is awarded by an independent test house (notified body) and shows the fires have been type tested to meet the essential requirements of the European Gas Appliance Regulations and the appropriate British Standards.
  • Page 3: General Requirements

    The installation must also be in accordance with the relevant parts of local and national building regulations and in accordance with BS5871 pt4 except where Burley instruction state differently. For the Republic of Ireland, reference should be made to IS813 and ICP3 and any guidance notes from Bord Gais.
  • Page 4: Installation Instructions

    INSTALLATION INSTRUCTIONS Before working on pipe work, plug the ends to prevent the entry of debris. Decide upon the route for the gas and lay pipes as required. Where pipes pass through walls they must be sleeved. Before connecting any pipes to the appliance, fully purge pipes of debris or swarf etc. and connect the gas supply to the 8mm elbow on the fire.
  • Page 5 THE APPLIANCE IS NOT TO BE RECESSED INTO THE WALL FOR SAFETY AND OPERATIONAL REASONS The appliance is a flueless visual flame heater designed to be installed on to a flat wall. It MUST NOT BE INSET INTO THE WALL as this could block the inlet and outlet passageways from the fire leading to a hazard.
  • Page 6: Preparing The Appliance

    PREPARING THE APPLIANCE Unpack the heater. Ensure appliance is correctly marked for the gas it is to be used with. Take the appliance components and lay them out in an ordered manner. To prevent damage the decorative frame and fire bed components can be placed safely to one side. Note how the frame attaches to the fire.
  • Page 7 Pilot Burner Burner Outlet Control Receiver Unit Press the battery switch on the gas access cover to the O position. View from underside of appliance Battery Switch Battery Switch Undo the securing screw for the receiver holder on the right hand side of the appliance as shown below.
  • Page 8 Remove plastic cover & fit 4 AA batteries. If required connect the cables from the valve to the receiver as shown. Do not force the valve cable plug when inserting into the receiver – it only fits one way. (yellow Valve Cable Lead...
  • Page 9 Lighting the Appliance Ensure that the battery ON/OFF switch located on the receiver holder is in the ON position (I) & that the MAN/ON selection knob is also pointing upwards towards its ON position (see below). Gas rate adjusting knob Remote ON selector Remote Control Gas Valve...
  • Page 10 Battery Replacement Handset On the back of the handset remove the battery cover by pressing down the top of the cover & sliding it down. Remove & unclip the old battery & replace with a new PP3 9 volt battery. Receiver Unit (located on your right hand side behind the trim) Switch the battery isolator switch to the (O) position.
  • Page 11 10.3 If you have any questions or the fire is not operating correctly, phone the Burley help- line BEFORE you leave the installation. If the appliance is not fitted in strict accordance with these instructions, Burley cannot be held responsible for any damage caused and reserve the right to charge for any corrective work.
  • Page 12: Servicing Instructions

    SERVICING INSTRUCTIONS As with all gas appliances the unit must be serviced at least once per year, preferably at the beginning of the heating season. All servicing must be carried out by a qualified service person. Before commencing any servicing, ensure that the gas is turned off to the appliance and that the appliance is cool.
  • Page 13: Parts List

    Burley Appliances are the only company to bench run and thoroughly test every single Flueless gas fire it produces. Burley is in the unique position of knowing that every appliance leaves the factory in perfect working order.
  • Page 14 Flue Gas Analysers – Installation & Servicing Facts • Please read this sheet even if you have fitted our fires before. • Please leave this sheet with the customer as reference for future servicing of the appliance. • Please explain to the customer how the fire works and the details and facts listed on this sheet, particularly what the catalyst does and doesn’t do.
  • Page 15 After the equivalent of 30 years of use, the catalytic converter is as efficient as it was when brand new. Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency.
  • Page 16 Gas rating of Burley Flueless Appliances Burley’s Flueless Gas Appliances are all gas input rated in the factory and undergo further line tests for combustion, sooting and visual performance. For Installers who wish to gas input rate appliances we need to establish tolerances for pass and fail.
  • Page 17 The appliance has been used solely in accordance with the instruction book. • Any in guarantee work carried out by Burley Appliances will be charged for if the fault is caused by incorrect pressure or gas, incorrect installation, operator error, neglect or abuse.
  • Page 18 Disposal Recycling Information: The metallic & glass parts of the appliance & its packaging should be sorted for environmental-friendly recycling. WEEE: Dispose of electrical equipment in an environmentally correct manner. When disposing components containing Refractory Ceramic Fibres (RCF), we recommend that the items are not broken up, but are sealed within heavy duty polythene bags, and clearly labelled as RCF waste.
  • Page 19 Page 19 of 20...
  • Page 20 Burley Magiglo fires are protected by UK patents 2193802, 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd, Lands’ End Way, Oakham, Rutland, LE15 6RB Tel: 01572 725570 Fax: 01572 724390 www.burley.co.uk Email: info@burley.co.uk Page 20 of 20...