Page 1
BURLEY G4220 – 9 MODEL & G4230 - 9 FLUELESS GAS HEATER INSTALLATION, SERVICING & USER INSTRUCTIONS FOR USE IN THE COUNTRIES STATED ON THE DATA PLATE AND CARTON WITH NATURAL GAS G20 OR LPG PROPANE GAS G31 (REFER TO RATING LABEL)
Page 2
INTRODUCTION Thank you for choosing this burley product. All of our products carry a CE mark which is awarded by an independent test house (notified body) and shows the fires have been type tested to meet the essential requirements of the European Gas Appliance Directive and the appropriate British Standards.
Page 3
In the event of a gas leakage, the gas supply must be turned off and advice sought. Working surfaces include the air outlet grille, door and stove body. The heater must not be used in a room area of less than 30m3 in volume. To convert cubic feet (ft³) to cubic metre (m³) divide the room volume in cubic feet by 35.3.
Page 4
WARNINGS Read the instructions before using this appliance. This appliance requires installation by a competent qualified person. Use only in a correctly sized and ventilated area. Once the coals have been positioned in accordance with the installation instructions, they must not be moved except for servicing. The surfaces of the appliance become very hot during use.
Page 5
Top Clearance - The heat from the appliance is concentrated towards the front edge directly above the combustion products outlet. The clearances stated relate to a distance from the back edge of the stove. A non combustible shelf may be fitted to within 50mm of the top edge of the fire. Combustible material such as wood may be fitted to within 100mm of the sides of the firebox provided it protrudes no further forward than 100mm.
Page 6
Fitting back coal Take the ceramic back block and place into position as shown. The coal shapes should be facing you and the base of the coal locates behind the tags on the burner. 10 Fitting front Coal The front coal fits vertically between the burner and the front of the case as shown. The coal sits with the 4 coal shapes uppermost and coal profile facing you.
Page 7
If the pipes have not been purged of debris do it before lighting the appliance. Failure to do so will result in blockages within the burner and pilot. Burley Appliances is the only company to bench run and thoroughly test every single gas fire it produces.
Page 8
13 Spark Failure The gap between the pilot electrode and the pilot should be 3.5 – 4.5mm and normally adjustment is not necessary. If the igniter fails a lighted taper can be inserted into the pilot area when attempting to light the pilot and this should help the fire to light. 14 Thermostat A room temperature thermostat is attached to the inlet gas pipe.
Page 9
Accessories The range of accessories for this stove includes dummy flue kits, which simulate a real stovepipe and warming shelves. Consult your dealer or Burley for a full list of optional accessories and follow the instructions for their use. Using unapproved accessories could prove hazardous and will invalidate the warranty.
Page 10
Burley Appliances are the only company to bench run and thoroughly test every single Flueless gas fire it produces. Burley is in the unique position of knowing that every appliance leaves the factory in perfect working order.
Page 11
Additional Servicing and Technical Information Flue Gas Analysers – Installation & Servicing Facts • Please read this sheet even if you have fitted our fires before. • Please leave this sheet with the customer as reference for future servicing of the appliance. •...
Page 12
After the equivalent of 30 years of use, the catalytic converter is as efficient as it was when brand new. Burley manages to achieve this by designing the fire to ensure that the catalytic converter is in exactly the right position for long life and maximum efficiency. (For other makes of fire please consult the relevant manufacturer).
Page 13
Gas rating of Burley Flueless Appliances Burley’s Flueless Gas Appliances are all gas input rated in the factory and undergo further line tests for combustion, sooting and visual performance. For Installers who wish to gas input rate appliances we need to establish tolerances for pass and fail.
Page 14
The appliance has been used solely in accordance with the instruction book. • Any in guarantee work carried out by Burley Appliances will be charged for if the fault is caused by incorrect pressure or gas, incorrect installation, operator error, neglect or abuse.
Need help?
Do you have a question about the G4220 – 9 and is the answer not in the manual?
Questions and answers