Adjustment
5-7 PUNT ADJ
■ Adjustment objective: After replacing the MAIN PCB and BARREL, you must decide the AF search range so that the optimal
■ Necessary equipment: Infinity Callimator
<Adjustment method>
1. Save the adjustment file to the microSD
2. Refer to the following adjustment environment specification to adjust the focus.
1) Used specification of Infinity Callimator
- Set the illuminance specification of the Callimator to 6 LV.
- Maintain distance of less than 1cm between the end of the camera body tube to the lens surface of the Infinity Callimator.
- The camera must be fixed while the adjustment is made.
2) Used specification for infinite object
- The camera must be fixed with a tripod and leveled condition must be maintained.
- Set up the camera toward a building or object in infinite distance (more than 500m). (Do not use the chart)
- Set a cathedral, partment or object with high contrast in day environment/AF area display.
5-8
focus can be identified by the body tube.
card and install it on the camera.
TM
Infinity Callimator
Camera
Tripod
Fig. 5-5
SAMSUNG