  • Page 1 PENKO Engineering B.V. Your Partner for Fully Engineered Solutions Manual: SGM800 Digitizer Scan for manual For more information visit www.penko.com - technical support - literature library...
  • Page 2 If this Instruction Manual is not the processes. The use of non-specified ‘look- correct manual for the Penko product you alike’ substitution parts may result in the are using, call 0031(0)318-525630 for a risk of fire, electrical hazards, or improper replacement copy.
  • Page 3 Proper relay use and configuration is the responsibility of the user. Do not operate this instrument without the front cover being secured. Refer any installation, operation or servicing issues to qualified personnel. WWW.PENKO.COM Penko is an ETC Company e-mail: info@penko.com...
  • Page 4: Table Of Contents

    SGM800 Digitizer TABLE OF CONTENT Chapter Page 1. Loadcell power connection 1.1 SGM800 basic digitizer 1.2 SGM810 digitizer analog 1.3 SGM820 digitizer Ethernet 1.4 SGM830 digitizer CAN 1.5 SGM840 digitizer Profibus 1.6 SGM850 digitizer Serial 2.Indication of display 3. Explanation of front keys 4.
  • Page 5 6.17 Firmware update 7. Firmware update 8. Event Log 9. Alibi Memory 9.1 SGM800 Indicator Alibi Memory 9.2 SGM800 Controller CHK Alibi Memory 9.3 SGM800 Controller MFL Alibi Memory 10. Error codes 10.1 Weigher error codes 11. ASCII 11.1 ASCII protocol format 11.2 ASCII protocol commands...
  • Page 6: Loadcell Power Connection

    SGM800 Digitizer 1. Load cell / power connection 1.1 SGM800 basic digitizer...
  • Page 7: Sgm810 Digitizer Analog

    SGM800 Digitizer 1. Load cell / power connection 1.2 SGM810 digitizer analog...
  • Page 8: Sgm820 Digitizer Ethernet

    SGM800 Digitizer 1. Load cell / power connection 1.3 SGM820 digitizer ethernet...
  • Page 9: Sgm830 Digitizer Can

    SGM800 Digitizer 1. Load cell / power connection 1.4 SGM830 digitizer CAN...
  • Page 10: Sgm840 Digitizer Profibus

    SGM800 Digitizer 1. Load cell / power connection 1.5 SGM840 digitizer Profibus...
  • Page 11: Sgm850 Digitizer Serial

    SGM800 Digitizer 1. Load cell / power connection 1.6 SGM850 digitizer Serial...
  • Page 12: Indication Of Display

    SGM800 Digitizer 2. Indication of Display With cover closed 1. Weigher stable 4. Output active 1-4 2. Zero active 5. Weigher value 3. Tare active With cover opened key 1 press <2sec.= key 2 press <2sec.= key 1 press >2sec.= key 2 press >2sec.=...
  • Page 13: Explanation Of Front Keys

    SGM800 Digitizer 3. Explanation of front keys All keys have different functions depending if you are in weighing or menu mode. Pressing key 1 “short”. In Weighing mode: create a new zero level. In Menu mode: increase value by 1 or move up in menu.
  • Page 14: First Use Of Indicator

    SGM800 Digitizer 4. First use of indicator 4.1 First use of indicator -Configuration menu structure- - - - Fun setpoint function settings (not for SGM810 or controller) - - - ACn setpoint action settings (not for SGM810 or controller) - - - dAC...
  • Page 15: Display Indication At Startup

    SGM800 Digitizer 4. First use of indicator 4.2 Display indication at startup The start Turn the indicator on by connecting it to the power supply. A series of display will appear: Dislay test. All LED will turn on to confirm that the device display is functioning correctly.
  • Page 16: Weigher Setting

    SGM800 Digitizer 4. First use of indicator 4.3 First use of indicator -Weigher settings- Set up the correct indicator setting (step size and decimal point position). Turn the indicator on by connecting it to the power supply. Press key 3 for >2...
  • Page 17 SGM800 Digitizer First use of indicator -continue- When the maximum net weight value is set succesfully, the following screen is visible: Dis- play step size Press key 1 <2 sec. untill you see Ind 5 and press key 2 <2 sec.
  • Page 18 SGM800 Digitizer First use of indicator -continue- Press key 1 to define the point position and confirm by pressing key 3 for >2 sec. Left Right Confirm Done succesfully, the following screen is visible: Press key 3 <2 sec to go back to Configuration Menu.
  • Page 19 SGM800 Digitizer First use of indicator -continue- 4.4 First use of indicator -Calibration- Press key 3 for >2sec. to get in to Configuration Menu. (In SGM810 or controller) Go to the Calibration parameters by pressing key 1 <2 sec. until you see - - - CAL Check and delete calibration points.
  • Page 20 SGM800 Digitizer First use of indicator -continue- Calibration Settings -continue- When a number is shown, the deletion of one calibration point is completed and more points need to be deleted. Press key 3 >3 sec to do so. >3 sec.
  • Page 21: Calibration

    SGM800 Digitizer First use of indicator -continue- Calibration Settings -continue- The indicator now shows CP2 to calibrate the gain point (CP2). And will automatically jump to: Use key 1 and key 2 to enter the reference value. Key 1 is used for changing the number (1-9), key 2 is used for changing the position of the cursor.
  • Page 22: First Use By Using Pi Mach Ii Software

    The SGM can also be configured for first use by using PI mach II software. Download Penko Suite from the PENKO website (http://www.penko.com/db/ downloads/) and install Penko Suite. The following items will be installed: *Pi Mach II Program Interface to configure all Penko devices...
  • Page 23 First use by using PI Mach II software -continue- The following screen appears: In the Usb tab sheet click Discover, select the SGM800 Digitizer and click OK. If this doesn’t work, make sure other USB devices like mobile phones are disconnected from the PC.
  • Page 24 SGM800 Digitizer First use of indicator -continue- First use by using PI Mach II software -continue- Go to Start Quick setup and click the button: The follo- wing tree is shown: Use step 1 to set the Weigher Parameters: The settings you can make are: Unit: set the weigher unit (kg, lbs, T, etc.) this will be shown in PI.
  • Page 25 SGM800 Digitizer First use of indicator -continue- First use by using PI Mach II software -continue- Use step 2 to select the type of indicator: Set the type of weighing the SGM will be used for. This will automaticly set the most common filter settings to get a stable weigher signal.
  • Page 26 SGM800 Digitizer First use of indicator -continue- First use by using PI Mach II software -continue- Use step 4 to set the communication (different for every type): SGM820 (Ethernet): Here you can set: Name: here you can give the SGM820a name. Example “platform 1”.
  • Page 27 Buslink Subaddress: Set the Buslink Subaddress for the communication between PENKO devices. Baudrate: Set the commication speed of the SGM830 options are: 100k, 125k, 250k, 500k. (the speed of all PENKO devices in the communication bus must be the same). SGM840 (PROFIBUS):...
  • Page 28 SGM800 Digitizer First use of indicator -continue- First use by using PI Mach II software -continue- SGM850 (Serial): Here you can set (for both RS232 and RS422): Protocol: Set the Protocol that is used on the serial port. Options are: None, Printerm ASCII, NPV Slave, Mudbus RTU, Modbus ASCII.
  • Page 29 SGM800 Digitizer First use of indicator -continue- First use by using PI Mach II software -continue- Use Done to finish the quick setup. Click End Quick setup: Click Enable Full setup to gain access to all settings (optional): The following tree is shown and gives access to all settings:...
  • Page 30: Main Menu

    SGM810 or controllers), display the TAC code and display the CAL code. 5.1 Setpoints. (this option is not available in the SGM810) The SGM800 has four outputs that can switch on/off on different levels. These levels have to be filled in at the setpoint menu.
  • Page 31: Tac (Traceable Acces Code)

    5.2 TAC code (Traceable Acces Code). The SGM800 has a TAC code inside. TAC code is number of times the indicator data is changed. When an indicator gets certified this number will be written on the device and is used by the controlling agency to see if the settings aren’t changed after sealing.
  • Page 32: Cal (Calibration Counter)

    Main Menu -continue- 5.2 CAL code (Calibration counter). The SGM800 has a CAL code inside. CAL code is the number of times the calibration is changed. When an indicator gets certified this number will be written on the device and is used by the controlling agency to see if the settings aren’t changed after sealing.
  • Page 33: Configuration Menu

    SGM800 Digitizer 6. Configuration Menu Press button 3 >2 sec to enter the Configuration Menu. In the Configuration Menu the following options are available: - - - Fun - - - Fun setpoint function settings (not for SGM810) setpoint function settings (not for SGM810 or controller)
  • Page 34: Setpoint Function Settings (Not For Sgm810)

    SGM800 Digitizer Configuration Menu -Fun- 6.1 - - - Fun setpoint function settings (not for SGM810 or controller) Configure the weiger mode the outputs has to switch on press key 2 <2 sec to enter the setpoint function settings menu.
  • Page 35: Setpoint Action Settings (Not For Sgm810)

    SGM800 Digitizer Configuration Menu -ACn- 6.2 - - - ACn setpoint action settings (not for SGM810 or controller) To set the hysteresis for the outputs press key 2 <2 sec to enter the setpoint function settings menu. Select the output you want to configure pressing key 1 <2 sec. Acn 1= output 1, Acn 2= output 2, Acn 3= output 3 and Acn 4= output 4.
  • Page 36 SGM800 Digitizer Configuration Menu -ACn- -continue- Positive hysteresis Negative hysteresis...
  • Page 37: Analog Output Settings

    SGM800 Digitizer Configuration Menu -dAC- 6.3 - - - dAC Analog output settings In this menu, all analog output parameters can be set (only for SGM810 or when the analog output option is installed).Options are: dAC 1 Set analog output to minimum level...
  • Page 38 SGM800 Digitizer Configuration Menu -dAC- -continue- In dAC 2 you can set the analog output to its maximum level for testing purpo- se.Press key 2 <2 sec to set the analog output to maximum. Press key 3 <2 sec to go back.
  • Page 39 SGM800 Digitizer Configuration Menu -dAC- -continue- The options are: Weigher 10 Fast gross x 10 Fast gross 11 Fast Net x 10 Fast net 12 Display Gross x 10 Display Gross 13 Display Net x 10 Display Net 14 Tare x 10...
  • Page 40 SGM800 Digitizer Configuration Menu -dAC- -continue- The following screen will be vissable: In dAC 6 you set the weigher end value for the analog output. At this value the analog output stops with its maximum value. Press key 2 < 2sec. to enter dAC 6.
  • Page 41: Local Bus Communication Settings (Rs485)

    The following screen will be vissable: In 485 1 you set the address of the SGM800. Press key 2 < 2sec. to enter 485 1. Set the address using key 1 and key 2.. Key 1 is for changing the number (1-9), key 2 is for changing the position of the cursor.
  • Page 42: Ethernet Settings (Sgm820 Only)

    Ethernet settings (SGM820 only) Protocols that can be used are Ethernet IP, Omron Fins and Modbus TCP. For protocol description please download PENKO Suite from www.penko.com In this menu, the communication settings can be set for the ethernet port. Options are:...
  • Page 43 SGM800 Digitizer Configuration Menu -Eth- -continue- In Adr 1 you set the first three numbers of the IP address you want to give the SGM820 (example: 192.168.151.112). Use key 1 and key 2 to change the number Key 1 is for changing the number (1-9), key 2 is for changing the position of the cursor.
  • Page 44 SGM800 Digitizer Configuration Menu -Eth- -continue- When confirmed the following screen will be visible: In Adr 4 you set the fourth three numbers of the IP address you want to give the SGM820 (example: 192.168.151.112). Use key 1 and key 2 to change the num- ber Key 1 is for changing the number (1-9), key 2 is for changing the position of the cursor.
  • Page 45 SGM800 Digitizer Configuration Menu -Eth- -continue- Increase Decrease Left Right Confirm When confirmed the following screen will be visible: In Sub 3 you set the third three numbers of the Subnet address you want to give the SGM820 (example: 255.255.255.000). Use key 1 and key 2 to change the number Key 1 is for changing the number (1-9), key 2 is for changing the position of the cursor.
  • Page 46 SGM800 Digitizer Configuration Menu -Eth- -continue- In gAt 1 you set the first first numbers of the Gateway address you want to give the SGM820 (example: 192.168.001.001). Use key 1 and key 2 to change the number Key 1 is for changing the number (1-9), key 2 is for changing the position of the cursor.
  • Page 47 Confirm by pressing key 3 >2 sec. Increase Decrease Left Right Confirm When confirmed the following screen will be visible: Starting at firmware version 1.5.0.9.0.1 the PENKO ASCII protocol is available over TCP at port 23.
  • Page 48 The following screen will be vissable: In CAn 1 you set the Canbus protocol of the SGM800. Press key 2 <2 sec. to enter CAn 1. Set the protocol using key 1 and key 2 confirm by pressing key 3 >2 sec. 1=...
  • Page 49 SGM800 Digitizer Configuration Menu –Can- -continue- In CAn 2 you set the Canbus address of the SGM800. Up to 8 devices can com- municate with eachother, sharing inputs, outputs, markers and indicators. Press key 2 <2 sec. to enter CAn 2. Set the address using key 1 and key 2 confirm by pressing key 3 >2 sec.
  • Page 50 SGM800 Digitizer Configuration Menu –Can- -continue- In CAn 4 you set the Canbus Baudrate of the SGM800. Set the communication speed using key 1 and key 2 confirm by pressing key 3 >2 sec. (options are: 1= 100kbps, 2=125kbps, 3=250kbps and 4=500kbps).
  • Page 51: Profibus Settings (Sgm840 Only)

    SGM800 Digitizer Configuration Menu –Pb- 6.7 - - - - Pb Profibus settings (SGM840 only) For GSD file and protocol description please download PENKO Suite from www.penko.com. In this menu, the communication settings can be set for profibus. Options are:...
  • Page 52 SGM800 Digitizer Configuration Menu -Pb- -continue- In Pb 2 you set the profibus Value mode. The profibus value can be shown as Integer (direct value without decimal point) or as Floating Point (real value with decimal point). Press key 2 <2 sec. to change the mode.
  • Page 53: Rs232 Port Settings (Sgm850 Only)

    232 1. Set the Prot using key 1 and key 2 confirm by pressing key 3 >2 sec. (options are: 1= None, 2= Printer, 3= ASCII, 4= NPV Slave, 5= Modbus-RTU, 6= Modbus ASCII). For protocol descriptions please download PENKO Suite from www.penko.com...
  • Page 54 SGM800 Digitizer Configuration Menu –232- -continue- When confirmd the following screen will be vissable: In 232 2 you set the RS232 address of the SGM850. Press key 2 <2 sec. to enter 232 2 Set the address using key 1 and key 2 confirm by pressing key 3 >2 sec.
  • Page 55 SGM800 Digitizer Configuration Menu –232- -continue- In 232 4 you set the RS232 Parity of the SGM850. Press key 2 <2 sec. to enter 232 4 Set the Parity using key 1 and key 2 confirm by pressing key 3 >2 sec.
  • Page 56 SGM800 Digitizer Configuration Menu –232- -continue- In 232 6 you set the RS232 ASCII Indicator of the SGM850. This setting only ta- kes effect when using the ASCII protocol. Press key 2 <2 sec. to enter 232 6 Set the Indicator numer that you want to sent out over the RS232 port by using key 1 and key 2 confirm by pressing key 3 >2 sec.
  • Page 57: Rs422 Port Settings (Sgm850 Only)

    422 1. Set the Prot using key 1 and key 2 confirm by pressing key 3 >2 sec. (options are: 1= None, 2= Printer, 3= ASCII, 4= NPV Slave, 5= Modbus-RTU, 6= Modbus ASCII).For protocol descriptions please download PENKO Suite from www.penko.com...
  • Page 58 SGM800 Digitizer Configuration Menu –422- -continue- When confirmd the following screen will be vissable: In 422 2 you set the RS422 address of the SGM850. Press key 2 <2 sec. to enter 422 2 Set the address using key 1 and key 2 confirm by pressing key 3 >2 sec.
  • Page 59 SGM800 Digitizer Configuration Menu –422- -continue- In 422 4 you set the RS422 Parity of the SGM850. Press key 2 <2 sec. to enter 422 4 Set the Parity using key 1 and key 2 confirm by pressing key 3 >2 sec.
  • Page 60 SGM800 Digitizer Configuration Menu –422- -continue- In 422 6 you set the RS422 ASCII Indicator of the SGM850. This setting only ta- kes effect when using the ASCII protocol. Press key 2 <2 sec. to enter 422 6 Set the Indicator numer that you want to sent out over the RS424 port by using key 1 and key 2 confirm by pressing key 3 >2 sec.
  • Page 61: Indicator Settings

    SGM800 Digitizer Configuration Menu -Ind- 6.10 - - - Ind Indicator settings In this menu, the Indicator settings can be set. Options are: Ind 1 Maximum display value Ind 2 No motion band Ind 3 Stable time Ind 4 Digital overall filter...
  • Page 62 SGM800 Digitizer Configuration Menu -Ind- -continue- The following screen is vissable: Use key 1 and 2 to change the value. Key 1 is for changing the number (1-9), key 2 is for changing the position of the cursor. Confirm by pressing key 3 for >2 sec.
  • Page 63 SGM800 Digitizer Configuration Menu -Ind- -continue- The following screen is vissable: In Ind 3 you set the Stable time Indicator gives stable signal when weigher value is stable within the range set in Ind 2 and time set with Ind 3.
  • Page 64 SGM800 Digitizer Configuration Menu -Ind- -continue- To change the filter press key 2 < 2 sec. The following screen is vissable: Use key 1 change the filter. Confirm by pressing key 3 for >2 sec. Down Confirm The following screen is vissable: In Ind 5 you set the display step size.
  • Page 65 SGM800 Digitizer Configuration Menu -Ind- -continue- Use key 1 to select the correct step size. Choose between 1, 2, 5, 10, 20, 50 and confirm by pressing key 3 for >2 sec. Example step size: weigher value is 2005 kg...
  • Page 66 SGM800 Digitizer Configuration Menu -Ind- -continue- The following screen is vissable: In Ind 7 you set the Display refreshment speed. The Display refreshment speed defines the times the weigher value is refresht per second. Options are: 1, 2, 3, 5, 10, 25, 50.
  • Page 67 SGM800 Digitizer Configuration Menu -Ind- -continue- In Ind 8 you set the operation mode of the SGM800. Set the operation mode of the unit to Industrial or Certified. In Industrial mode it’s always possible to change the indicator parameters and calibration. In certified mode the unit will be sealed by marks and also the weighing parameters will be blocked to satisfy to the cali- bration laws.
  • Page 68: Multi Range/Interval Settings

    SGM800 Digitizer Configuration Menu -Ind- -continue- To change the sample rate press key 2 < 2 sec. The following screen is vissable: Press key 1 to choose the sample rate and confirm by pressing key 3 for >2 sec. Down Confirm...
  • Page 69 SGM800 Digitizer Configuration Menu -rng- -continue- The following screen is visable: In rng 1 you set the number of display divisions. Set the number of divisions when the indicator has to display with the next step size. Auto ranging starts with step size set at Ind 5 and is disabled when range size is set to 0.
  • Page 70 SGM800 Digitizer Configuration Menu -rng- -continue- To change the maximum step size press key 2 < 2 sec. The following screen is vissable: Use key 1 change the filter. Key 1 is for changing the number. Confirm by pressing key 3 for >2 sec.
  • Page 71: Filter Settings

    SGM800 Digitizer Configuration Menu -rng- -continue- In rng 3 you set the auto range reset option. Choose between: oF: Multi Range = the highest shown step size will be reseted after the signal has been lower or equal to zero on: Mulit Interval = the highest shown step size will be reseted after the signal reaches the previous range.
  • Page 72 SGM800 Digitizer Configuration Menu -FIL- -continue- The following screen is visible: In FIL 1 you can set the display filter band. Set the band where the filter is active. This parameter works together wit FIL 2. Choose a value between –99999 kg and 999999 kg.
  • Page 73 SGM800 Digitizer Configuration Menu -FIL- -continue- The following screen is visible: Use key 1 change the filter. Confirm by pressing key 3 for >2 sec. Down Confirm The following screen is visible: In FIL 3 you set the band within the indicator will show 0.
  • Page 74 SGM800 Digitizer Configuration Menu -FIL- -continue- In FIL 4 you can set the number of the indicator shown in the display. Choose a number between 1 and 17. When using the FIL parameters use 4, 5, 12 or 13. The following...
  • Page 75: Digital Filter Settings

    SGM800 Digitizer Configuration Menu -dSF- 6.13 - - - dSF Digital filter settings In this menu, the digital filter settings can be set. This filter is a 2 order filter. The filter effects all signals up to and including the cutoff frequency. Options are:...
  • Page 76 SGM800 Digitizer Configuration Menu -dSF- -continue- The following screen is visible: In dSF 2 you can set the Cutoff frequency. Determines the range used for filtering the signal. Choose between oFF, 1.0Hz, 1.4Hz, 2.5Hz, 5.0Hz, 10.0Hz, 20.0Hz and 40Hz. Press key 2 <2 sec. to change the cutoff frequency range.
  • Page 77: Pre-Calibration Settings 77

    SGM800 Digitizer Configuration Menu -PCL- Use key 1 and 2 to change the value. Key 1 is for changing the number (1-9), key 2 is for changing the position of the cursor. Confirm by pressing key 3 for >2 sec.
  • Page 78 SGM800 Digitizer Configuration Menu -PCL- -continue- In PcL 1 you can set the polaritiy of the input range. Un=Unipolar mode the input range for load cells is –0.2 mV/V to + value set at Range. Bi=Bipolar mode the input range for load cells is –value set at Range to + value set at Range.Press key 2 <2 sec.
  • Page 79 SGM800 Digitizer Configuration Menu -PCL- -continue- Use key 1 change the sensitiviy. Confirm by pressing key 3 for >2 sec. Down Confirm The following screen is visible: In PcL 3 you can set the Input offset. Choose bet- ween choose a sample value between –50000 and 50000. Press key 2 <2 sec. to...
  • Page 80: Calibration Settings

    SGM800 Digitizer Configuration Menu -PCL- -continue- The following screen is visible: The following screen is visible: To recall the factory settings press key 3 >2 sec. cancel press key 3 <2 sec. Cancel Recall The following screen is visible: Configuration Menu -CAL- 6.15 - - - CAL...
  • Page 81 SGM800 Digitizer Configuration Menu -CAL- -continue- Press key 2 <2 sec to enter the calibration settings. The following screen is visible: In CAL 1 you can set the calibration points for the weigher. Press key 2 <2 sec. to set the calibration points.
  • Page 82 SGM800 Digitizer Configuration Menu -CAL- -continue- The indicator now shows CP2 to calibrate the gain point (CP2). And will automatically jump to: Use key 1 and key 2 to enter the reference value. Key 1 is used for changing the number (1-9), key 2 is used for changing the position of the cursor.
  • Page 83 SGM800 Digitizer Configuration Menu -CAL- -continue- Use key 1 <2 sec. to toggle between the actual weight and the actual weight x10. Use key 2 <2 sec. to toggle between the actual weight and the ADC value. When finished press key 3< 2 sec.
  • Page 84 SGM800 Digitizer Configuration Menu -CAL- -continue- When a number is shown, the deletion of one calibration point is completed and more points need to be deleted. Press key 3 >3 sec to do so. >3 sec. When all calibration points are deleted, the following screen is visible: In CAL 4 you can set a Deadload compensation.
  • Page 85: Theoretic Calibration

    SGM800 Digitizer Configuration Menu -CAL- -continue- Normally, the deadload is zero, but it is possible to change the line position if there is weight on the scale. To do so, edit the actual weigh value to the new known value.
  • Page 86 SGM800 Digitizer Configuration Menu -tCL- -continue- Press key 2 <2 sec to enter the theoreatic calibration settings. The following screen is visible: In tcL 1 you can set the maximum loadcell load. When more then one loadcell is used all loadcells should have the same maximum load. Press key 2 <2 sec. to set the maximum load.
  • Page 87 SGM800 Digitizer Configuration Menu -tCL- -continue- The following screen is visible: Use key 1 and key 2 to enter the sensitivitiy of loadcell 1. Key 1 is used for changing the number (1-9), key 2 is used for changing the position of the cursor.
  • Page 88 SGM800 Digitizer Configuration Menu -tCL- -continue- Use key 1 and key 2 to enter the sensitivitiy of loadcell 2. Key 1 is used for changing the number (1-9), key 2 is used for changing the position of the cursor. Sensitivity has to be filled in as 0.00000 mV/V. Press key 3 >2 sec. to set the sensitivity of the loadcell.
  • Page 89 SGM800 Digitizer Configuration Menu -tCL- -continue- The following screen is visible: In tcL 5 you can set the loadcell sensitivity for loadcell 4. This information can be found on the datasheet deliverd with the loadcell. Press key 2 <2 sec. to set the loadcell sensitivity.
  • Page 90: Geographic Calibration

    SGM800 Digitizer Configuration Menu -gCL- 6.17 - - - gCL Geographic calibration In this menu, the Geographic calibration settings can be set. Here you can set a geographic information of the loadcells filled in al tCL. Options are: gCL 1...
  • Page 91 SGM800 Digitizer Configuration Menu -gCL- -continue- Down Left Right Confirm The following screen is visible: In gcL 2 you can set the origin elevation of the loadcell. This is the geographic elevation of where the loadcell is manufactured. Press key 2 <2 sec. to set the origin elevation.
  • Page 92 SGM800 Digitizer Configuration Menu -gCL- -continue- In gcL 3 you can set the location latiude of the loadcell(s). This is the geographic latitude of where the loadcell is going to be used. Press key 2 <2 sec. to set the location latitude.
  • Page 93: Date And Time Configuration (Sgm850 Only)

    SGM800 Digitizer Configuration Menu -gCL- -continue- Use key 1 and key 2 to enter the location elevation of the loadcell(s). Key 1 is used for changing the number (1-9), key 2 is used for changing the position of the cursor. And press key 3 >2 sec.to set the location latitude. Choose value between –1000 and 30000 meter...
  • Page 94: Recall

    SGM800 Digitizer Configuration Menu -CLo- -continue- The following screen is visible: Set the time. Use key 1 and key 2 to change the number Key 1 is for changing the number (1-9), key 2 is for changing the position of the cursor. Confirm by pressing key 3 >2 sec.
  • Page 95 Starting at firmware version 1.6.0.9.0.3 a backup of the device configuration can be made within the device. A password is required for the backup. Contact PENKO for this password. The backup can only be made using Pi Mach II manage. Enter the password in the service code field.
  • Page 96: Firmware Update

    The device restarts after a restore action. Configuration Menu -SoF- 6.20 - - - SoF Firmware update In SoF, you can set the SGM800 in boot mode for software update. Press key 2 <2 sec to enter Boot mode. The following screen is visible: Press key 3 >2...
  • Page 97: Firmware Update

    SGM800 Digitizer 7. Firmware update Connect the SGM to the computer through USB. Start PI Mach II. Set communi- cation to USB. Start the Firmware Update Manager. Click Open and select the PIP file. Click Search For Devices and select the device with source “0”.
  • Page 98 Press key 2 <2 sec to enter Boot mode. The following screen is visible: Press key 3 >2 sec to set the SGM800 in Boot mode. click Firmware Update to start the update. SGM will reboot automatically and the Firmware Up- date...
  • Page 99: Event Log

    Calibrations. Event Logs can be viewed via Pi Mach II Manage: How you can connect your SGM800 to PI Mach II Manage is explained in chapter 4.4 of this manual. Enter the Event number at “Entry Number” and confirm with Enter or the Apply button.
  • Page 100: Alibi Memory

    Memory has no function. The Alibi memory can be viewed via Pi Mach II Manage: How you can connect your SGM800 to PI Mach II Manage is explained in chapter 4.4 of this manual. Events can only be printed with the SGM850 Serial.
  • Page 101: Sgm800 Indicator Alibi Memory

    SGM800 Digitizer 9. Alibi Memory -continue- 9.1 SGM800 Indicator Alibi Memory An input can be programmed as PRINT command. Every time the PRINT command is executed, the current weigher value is written to the Alibi Memory. Enter the Alibi number at “Entry Number” and confirm with Enter or the Apply but- ton.
  • Page 102: Sgm800 Controller Chk Alibi Memory

    SGM800 Digitizer 9. Alibi Memory -continue- 9.2 SGM800 Controller CHK Alibi Memory In the SGM800 CHK the Alibi Memory can be enabled in the configuration. For more information about the configuration please check the SGM800 Check weigher manual supplement. To get the Alibi information enter the Alibi number at “Entry Number” and confirm with Enter or the Apply button.
  • Page 103: Sgm800 Controller Mfl Alibi Memory

    SGM800 Digitizer 9. Alibi Memory -continue- 9.3 SGM800 Controller MFL Alibi Memory In the SGM800 MFL the Alibi Memory can be enabled in the configuration. For more information about the configuration please check the SGM800 Mono Filler manual supplement. To get the Alibi information enter the Alibi number at “Entry Number” and confirm with Enter or the Apply button.
  • Page 104: Error Codes

    SGM800 Digitizer 10. Error Codes Error Code Description Solution 2001 Parameter error Invalid entry, choose a valid value Invalid entry, choose value within 2005 Input value is not valid range Wait for stable weigher signal and try 2101 Weigher not stable...
  • Page 105: Weigher Error Codes

    SGM800 Digitizer 10.1 Weigher error Codes Error Code Description Solution CCCCCC No proper calibration available Check calibration setting Check loadcell UUUUUU Underflow Check platform construction Check loadcell OOOOOO Overflow Check platform construction Display overflow; Exceed maximum display ====== Reduce load on platform value (max.
  • Page 106: Ascii Protocol Commands

    SGM800 Digitizer 11.2 ACSII -Protocol Commands- Command Respons strings Operation OP <number><CR> OK<CR>/ERR<CR> Open channel connection CL<CR> Close channel connection SZ<CR> OK<CR>/ERR<CR> Set Zero value OK<CR>/ERR<CR> RZ<CR> Reset Zero value OK<CR>/ERR<CR> ST<CR> Set Tare OK<CR>/ERR<CR> RT<CR> Reset Tare OK<CR>/ERR<CR> PT<value><CR>...
  • Page 107 SGM800 Digitizer 11.2 ACSII -protocol commands - continue- Command Respons strings Operation LN<CR> N+00000+00000SSCC<CR>/ERR<CR> Get net+fast net , status & checksum Get long extended net (net x 10) + LX<CR> X+00000+00000SSCC<CR>/ERR<CR> extended gross (gross x 10), status & checksum SD<CR>...
  • Page 108: Profibus Protocol Description

    SGM800 Digitizer 12. Profibus Protocol Description Note that the GSD Profibus file for the SGM840 Indicator differ from SGM840 controller GSD file. Use PSGM0E28.GSD This file is available in the Penko Suite. Inputs to PLC D word 32 bit Weight register...
  • Page 109: Standard Factory Settings

    SGM800 Digitizer 13. Standard Factory Settings Description Display Value Your setting Setpoint function Fun 1 Fun 2 Fun 3 Fun 4 Setpoint action Acn 1 000,010 Acn 2 000,010 Acn 3 000,010 Acn 4 000,010 Analog output dAC 4 dAC 5 000.000...
  • Page 110 SGM800 Digitizer 13. Standard Factory Settings -continue- Description Display Value Your setting Ethernet gAT 1 gAT 2 gAT 3 gAT 4 Indicator Ind 1 10.009 Ind 2 Ind 3 1.000 Ind 4 Ind 5 Ind 6 - - - . - - -...
  • Page 111 SGM800 Digitizer 13. Standard Factory Settings -continue- Description Display Value Your setting Pre-calibration Pcl 1 Pcl 2 Pcl 3 Theoretic calibration tCL 1 10.000 tCL 2 0.000 tCL 3 0.000 tCL 4 0.000 tCL 5 0.000 Geographic calibration gCL 1 52.00...
  • Page 112: Appendix I

    SGM800 Digitizer Appendix I Description Definition Weight filtered net weigher value that can react on mulit range/interval Fast Gross unfiltered gross weigher value Fast Net unfiltered net weigher value Display Gross filtered gross weigher value Display Net filtered net weigher value...
  • Page 113 Our design expertise include systems for manufacturing plants, bulk weighing, check weighing, force measuring and process control, For over 35 years, PENKO Engineering B.V. has been at the forefront of development and production of high-accuracy, high-speed weighing systems and our solutions continue to help cut costs, increase ROI and drive profits for some of the largest global brands, such as Cargill, Sara Lee, Heinz, Kraft Foods and Unile- ver to name but a few.