from the AC line. Earth grounding
signal connections will damage the
drive and void the warranty. It is
recommended that the ID5SI-1
Signal Isolator and Run/Fault Relay
be installed when using signal
following.
Catalog Nos. ID5401-CO, ID5402-
CO, ID5403-CO, ID5405-CO: The
ID5SI-1 is factory calibrated for 0 to
±5 Volt DC signal input. Connect the
voltage (0 to ±25 Volt DC) or current
(4 – 20 mA DC) signal input to
Terminals "SIG1" (+) and "COM1" (–)
of Terminal Block TB1 on the
ID5SI-1. For voltage following, be
sure Jumper J1 (on the ID5SI-1) is set
to the "VOLT" position (factory set-
ting). For current following, set
Jumper J1 (on the ID5SI-1) to the
"CUR" position. See Figures 11 and
12. A jumper must be installed
between Terminals "0V" and "FWD",
of Terminal Block TB1, in order for
the drive to operate.
Application Note: In the
Voltage Following Mode, the
input will accept a "+" and "–"
input voltage, which will run the
motor in the forward and
reverse direction.
Notes: 1. The MIN Trimpot
on Catalog Nos. ID5401-CO,
ID5402-CO, ID5403-CO,
ID5405-CO is not functional.
Use the OFFSET Trimpot on the ID5SI-1 to offset the signal input, as described in
Section 7.1, on page 22. 2. Do not use the MAX Trimpot on Catalog Nos. ID5401-CO,
ID5402-CO, ID5403-CO, ID5405-CO. Use the MAX Trimpot on the ID5SI-1 to scale the
signal input, as described in Section 7.2, on page 23.
5.6 Manual Start Switch Connection (CON1): The Manual Start Mode is used to manually
start the drive or restart the drive (reset) if a fault has occurred. To operate the drive in the
Manual Start Mode, remove the factory installed jumper on CON1 and install the 2-wire
connector (supplied). CON1 is located on the lower PC board. Connect CON1 to a
momentary switch or contact, as shown in Figure 13.
18
WARNING! The signal
input must be isolated
FIGURE 11 – CATALOG NOS. ID5401-CO,
ID5402-CO ID5403-CO, ID5405-CO
VOLTAGE FOLLOWING SIGNAL INPUT CONNECTION
(Jumper J1 Installed in "VOLT" Position)
+5V
-5V
0V
FIGURE 12 – CATALOG NOS. ID5401-CO,
ID5402-CO ID5403-CO, ID5405-CO
CURRENT FOLLOWING SIGNAL INPUT CONNECTION
(Jumper J1 Installed in "CUR" Position)
+5V
-5V
0V
FIGURE 13 – MANUAL START SWITCH CONNECTION
Jumper Removed
CON1
A/M
(0 to ±25 Volts DC)
0 to ±2.5 thru 0 to ±25
Volts DC
+ V -
Jumper
FWD
REV
SIG1 COM1
4 - 20 mA DC
-
+
Jumper
FWD
REV
SIG1
COM1
Connector Installed for
Manual Start Switch
Manual Start Switch
CON1
(Push to Run)
(Momentary Contacts)
Black
White
J1
ID5SI-1
TERMINAL
BLOCK
J1
ID5SI-1
TERMINAL
BLOCK