14.7 EEPROM Factory Default Data Setup Procedure

1
This process should be done at Gemstar (and/or) PAPAMY as the last process after any inspection.
2
This condition should be activated by pressing combination of few SW's for certain time as shown.
3
When this condition is activated, default data should be written in EEPROM.
4
Once the default data is written in the EEPROM, the following full LCD display should be ON for 2secs for
confirmation. After 2secs, it goes back to normal display.
These 3 SW's should press continuously for 5secs.
(Operation should be OFF during this period)
OPERATION
77