Panasonic WH-MHF09G3E5 Service Manual page 43

Air-to-water heatpump system. mono bloc unit
Hide thumbs Also See for WH-MHF09G3E5:
Table of Contents

Advertisement

11.4.4 Selecting The Installation Location
Remote control
Upper case
Lower case
Allow sufficient space around the remote control
(1) as shown in the illustration above.
11.4.5 Installing The Remote Control Unit To The Wall
Screw
driver
Gaps
1
Remove the remote control (1) lower case.
(Insert a flat-tipped screw driver or similar tool
2 to 3 mm into one of the gaps at the bottom
of the case, and twist to open. Refer to the
illustration above.)
Be careful not to damage the lower case.
2
Do not remove the protective tape which is
affixed to the upper case circuit board when
removing the remote control lower case.
3
Secure the lower case to an outlet box or wall.
Refer to (A) or (B) instructions below
depending on your choice of cable installation.
4
Be sure to use only the screws provided.
5
Do not over tighten the screws, as it may
result in damage to the lower case.
A. If Remote Control Cable Is Embedded
1
Embed an outlet box (JIS C 8336) into the
wall. Outlet box may be purchased separately.
Medium-sized square outlet box (obtain locally)
Part No. DS3744 (Panasonic Co., Ltd.) or
equivalent.
2
Secure the remote control lower case to the
outlet box with the two accessory screws (3).
Make sure that the lower case is flat against
the wall at this time, with no bending.
3
Pass the remote control cable (2) into the box.
4
Route the remote control cable (2) inside the
lower case through rear feeding-out direction.
5
Insert firmly the connector of remote control
cable (2) to connector (CON1) in the upper
case circuit board. [Refer to the illustration at
below.]
30mm or
more
30mm
30mm
or more
or more
Remote
control
lower case
120mm
or more
Upper case
Lower case
Screw (3) or
Screw (4)
Install in a place which is away from direct sunlight
and high humidity.
Install in a flat surface to avoid warping of the
remote control. If installed to a wall with an
uneven surface, damage to the LCD case or
operation problems may result.
Install in a place where the LCD can be easily
seen for operation. (Standard height from the floor
is 1.2 to 1.5 meters.)
Avoid installing the remote control cable near
refrigerant pipes or drain pipes, else it will cause
electrical shock or fire.
6
Secure the remote control upper case to the
lower case with the tabs provided.
Wall
Upper
case
Upper
tab
Connector
(CON1)
Lower
case
Screw (3)
Lower tab
When the wall is hollow, please be sure to use the sleeve for
remote control cable to prevent dangers caused by mice biting
the cable.
Remote control
cable (2)
Rear feeding-out
position
Lower case
43
Remote
control
cable
(2)
Outlet box (JIS C 8336)
CAUTION
Connector
(CON1)
Upper case
Upper case
Tabs
Lower case

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wh-mhf12g6e5

Table of Contents