Summary of Contents for Met One Instruments GT-526S

  • Page 1 GT-526S ANUAL Met One Instruments, Inc Corporate Sales & Service: 1600 NW Washington Blvd. Grants Pass, OR 97526 Tel (541) 471-7111 Fax (541) 471-7116 www.metone.com service@metone.com GT-526S Manual Rev F...
  • Page 2 Copyright Notice GT-526S Manual © Copyright 2012 Met One Instruments, Inc. All Rights Reserved Worldwide. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language in any form by any means without the express written permission of Met One Instruments, Inc.
  • Page 3: Table Of Contents

    5.5. Print Data Screen ........................14 5.6. Memory Screen ........................15 5.6.1. View Available Memory ..................... 15 5.6.2. Clearing Memory ....................... 15 5.7. Count Alarms Screen ......................15 5.7.1. Alarm Analog Output ......................16 GT-526S Manual Rev F Page 2...
  • Page 4 8.2. Zero Count Test ........................23 8.3. Flow Rate Test......................... 24 8.4. Annual Calibration ........................24 8.5. Flash Upgrade ......................... 24 Troubleshooting ....................25 10. Specifications ...................... 26 11. Warranty / Service ....................27 GT-526S Manual Rev F Page 3...
  • Page 5: Introduction

    Figure 2. Contact the supplier if any items are missing. ATTENTION: The included USB drivers must be installed before connecting the GT-526S USB port to your computer. If the supplied drivers are not installed first, Windows may install generic drivers that are not compatible with this product.
  • Page 6 PN 390031 Carrying Case USB Cable PN 8517 PN 500787 Figure 1 – Standard Accessories T/RH Probe Serial Cable Printer Flow Meter PN 3228 PN G3120 PN G3115 PN 9801 Figure 2 – Optional Accessories GT-526S Manual Rev F Page 5...
  • Page 7: Layout

    2.2. Layout The following figure shows the layout of the GT-526S and provides a description of each of the components. Inlet Nozzle (remove cap) T/RH Connector USB Port Serial Port Power Switch Charging Jack Figure 3 – GT-526S Layout Component...
  • Page 8: Default Settings

    2.4. Initial Operation Before operating the GT-526S for the first time, it is recommended that the unit be fully charged. Information regarding charging the battery is found in section 6 of this manual. Complete the following steps to verify proper operation.
  • Page 9: Operation

    The following sections cover the basic operation. 4.1. Power Up GT-526S power is controlled by a slide switch located on the right hand side of the unit. Move the power switch to the on position (towards the top of the case) to power up the unit.
  • Page 10: Sample Status

    1.0µ 610 CF Figure 6 – Operate Screen Sampling 4.2.2. Sample Status The top line of the Operate Screen displays the status of the GT-526S while the unit is sampling. The following table shows the various status messages: Status Description GT-526S is starting the sample and is waiting for the count STARTING…...
  • Page 11: Sample Related Functions

    Operate Screen or the menu. 4.3.2. Real-Time Serial Output GT-526S provides real-time output on the serial port at the end of each sample. The format of the output is controlled by the printer mode setting (section 5.2.4). Section 0 covers the real-time output format.
  • Page 12: Sample Timing

    About Screen 5.1. Edit Menu Items To change settings, press Menu to display the main menu, press ▲ or ▼ to navigate to the desired item and press Enter to display the item view/edit screen. GT-526S Manual Rev F Page 11...
  • Page 13: Sample Setup Screen

    Single configures the unit for a single sample. 002-999 Configures the unit to take N samples. 5.3. Settings Screen Figure 12 shows the Settings Screen. The 4 parameters are covered in the sections immediately following. GT-526S Manual Rev F Page 12...
  • Page 14: Volume

    Figure 12 – Settings Screen 5.3.1. Volume The GT-526S supports total counts (TC), particles per liter (/L), particles per cubic foot (CF), and particles per cubic meter (M3). Particle count information updates while the unit is sampling. Concentration values (/L, CF, M3) are time dependent so these values may fluctuate early in the sample;...
  • Page 15: Recall Data Screen

    After the print settings have been selected, the Printing Status Screen is displayed. Figure 17 shows the Printing Status Screen as it would look when finished. PRINTING STATUS SCANNING...15 PRINTING...10 FINISHED! Figure 17 – Printing Status Screen GT-526S Manual Rev F Page 14...
  • Page 16: Memory Screen

    5.6. Memory Screen The GT-526S memory is composed of a single file which contains the data from sample events. Every time a sample is completed, the GT-526S stores that data into the memory. The GT-526S memory is circular, meaning when the memory is full, the unit will start overwriting the oldest saved samples with new samples.
  • Page 17: Alarm Analog Output

    5.9. Set Flow Screen The GT-526S has a factory calibrated flow rate of 0.1 CFM (2.83 LPM). Use the following procedure to adjust the flow rate when a periodic flow rate check (Section 8.3) indicates a flow rate error greater than +/- 5%.
  • Page 18: Set Sizes Screen

    Figure 21 – Set Flow Screen 5.10. Set Sizes Screen The GT-526S has six standard factory calibrated particle sizes. These standard sizes will support most applications and provide the best size accuracy (+/- 10%). This unit also supports custom sizes. These sizes are configured using the Set Sizes Screen (Figure 22).
  • Page 19: Set Contrast Screen

    To charge the battery, connect the battery charger to an AC power outlet and the DC barrel connector to the socket on the right side of the GT-526S. The battery charger is universal and will work with power line voltages of 100 to 240 volts, 50 to 60 Hz. A discharged battery pack will take approximately 2.5 hours to fully charge.
  • Page 20: Serial Communications

    GT-526S. ATTENTION: The included USB drivers must be installed before connecting the GT-526S USB port to your computer. If the supplied drivers are not installed first, Windows may install generic drivers that are not compatible with this product..
  • Page 21: Serial Interface

    7.1. Serial Interface The serial interface to the GT-526S is through either the mini-USB or the 9 pin (DB-9) connector. They are located on the right hand side of the instrument as shown below. Communication with the GT-526S through the RS-232 DB-9 port requires a custom serial cable (PN3228).
  • Page 22: Commands

    7.2. Commands GT-526S provides serial commands for accessing stored data and settings. All commands are terminated by a carriage return. Also, these commands are not case sensitive. The following table lists the available commands. These commands are available via USB, RS232 and RS485 hardware interfaces. The settings (baud rate, parity and stop bits) must match the computer setting for proper communication regardless of the hardware interface type (USB, RS232 or RS485).
  • Page 23: Comma Separated Value (Csv) Output Format

    Note 2 Temperature (C,F) Note 2 & Note 3 RH (%) Note 3 Location Sample Time (0-999 seconds) Alarm 1 Size Note 4 Alarm 2 Size Note 4 Status Bits (see below) Note 5 GT-526S Manual Rev F Page 22...
  • Page 24: Printer Format

    Due to the nature of the instrument, there are no customer serviceable components in the GT-526S. The case of the GT-526S should never be removed or opened for any reason. Opening or removing the case of the GT-526S voids the warranty and may result in exposure to laser radiation, which can cause eye injury.
  • Page 25: Flow Rate Test

    4. Adjust the flow rate if the error is > ±5% (see section 5.7.1). 8.4. Annual Calibration The GT-526S should be sent back to Met One Instruments yearly for calibration and inspection. The annual calibration cannot be performed by the customer because this calibration requires specialized equipment and a skilled technician. Met One Instruments maintains a calibration facility for calibrating particle counters according to industry accepted methods such as ISO, JIS and NIST.
  • Page 26: Troubleshooting

    The GT-526S case should never be removed or opened for any reason. Opening or removing the case will void the warranty and may result in exposure to laser radiation, which can cause eye injury.
  • Page 27: Specifications

    AC Adapter / Battery Charger Iso-kinetic Sample Probe Carrying Case Zero Particulate Filter (PN G3111) Optional RH & Temperature Probe (PN G3120) Flow Meter (PN 9801) Portable Printer (PN G3115) Custom Serial Cable (PN 3228) GT-526S Manual Rev F Page 26...
  • Page 28: Warranty / Service

    Warranty / Service GT-526S Manual Rev F Page 27...