Hamworthy Trigon ST1 Installation, Commissioning, Operation & Service Instructions page 10

Solar pump station
Table of Contents

Advertisement

2 Safety instructions
CAUTION
Personal injury and damage to property due to overpressure!
By closing the two ball valves in the primary circuit you isolate the pressure relief
valve from the heat exchanger. A rise in temperature in the storage tank will
cause high pressures and could result in personal injury or damage to property!
 Only close the ball valves for service and maintenance.
NOTICE
Material damage due to mineral oils!
Mineral oil products cause lasting damage to seals made of EPDM, whereby the sealant
properties are lost. We do not assume liability nor provide warranty for damage to property
resulting from sealants damaged in this way.
 It is imperative to avoid that EPDM gets in contact with substances containing mineral
oils.
 Use a lubricant based on silicone or polyalkylene and free of mineral oils such as
Unisilikon L250L and Syntheso Glep 1 of the Klüber company or a silicone spray.
0DNO0201
Installation-Operation ST1 Solar Pump Station
7

Advertisement

Table of Contents
loading

Table of Contents