Download Print this page
Banner Sure Cross Performance P15E Node Series Manual

Banner Sure Cross Performance P15E Node Series Manual

Advertisement

Quick Links

Sure Cross
Performance P15E Node
®
Datasheet
®
The Sure Cross
wireless system is a radio frequency network with integrated I/O that operates in most environments to eliminate
the need for wiring runs.
The Performance Series P15E Node can wirelessly control any AC-powered devices, including lights (including dimming levels), fan
speed, and motors. For higher amperage applications, relays can be used to control contactors. By using a current transducer and
its analog inputs you can monitor energy/power levels for connected devices.
Benefits
Remotely control—Lights, fans, and motors; use in conjunction with equipment health monitoring sensors to shut down
motors remotely when potential issues are detected
Eliminate control wires—The Sure Cross wireless system is a radio frequency network with integrated I/O that removes the
need for control wires.
Reduce complexity—Facility or machine reconfiguration made easier; great for retrofit applications
Deploy easily—The relays and wireless radio are housed in a single device, simplifying installation on existing equipment
and enabling deployments in remote and hard-to-access locations where implementing a wired solution would be difficult,
impractical, or not cost-effective
For additional information, updated documentation, and a list of accessories, refer to Banner Engineering's website,
www.bannerengineering.com/wireless
WARNING:
Risk of Electric Shock
Disconnect or turn off the power before installing, removing, or servicing the P15E Node.
Install and connect the P15E Node in accordance with the National Electrical Code (NEC) and any
applicable local code requirements and supply the P15E Node with an appropriate fuse box or circuit
breaker (see Supply Voltage rating in the Specifications).
Install the P15E Node at the end of a conduit run.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or
death. This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized
sensor output condition.
CAUTION: Never Operate 1 Watt Radios Without Antennas
To avoid damaging the radio circuitry, never power up Sure Cross
Watt) radios without an antenna.
Original Document
197408 Rev. C
Wireless industrial I/O device with two AC/DC relay outputs, two discrete PNP outputs, two 0–
10 V dc analog outputs, two discrete NPN or PNP (selectable) inputs, and two 0–10 V dc
analog inputs
Supply voltage of 100–277 V ac at 50/60 Hz
Courtesy power output of 25 W (24 V dc)
AC power field wireable through a 1/2-inch NPSM port using 1/2-inch conduit, cable gland, or
Mini-style quick disconnect (QD)
Selectable transmit power levels of 250 mW or 1 Watt for 900 MHz models and 65 mW for 2.4
GHz models
DIP switches for user configuration
Frequency Hopping Spread Spectrum (FHSS) technology ensures reliable data delivery within
the unlicensed Industrial, Scientific, and Medical (ISM) band
Transceivers provide bidirectional communication between the Gateway and Node, including
fully acknowledged data transmission
Lost RF links are detected and relevant outputs set to user-defined conditions
.
19 April 2018
®
Performance or Sure Cross MultiHop (1
197408

Advertisement

loading

Summary of Contents for Banner Sure Cross Performance P15E Node Series

  • Page 1 Transceivers provide bidirectional communication between the Gateway and Node, including fully acknowledged data transmission • Lost RF links are detected and relevant outputs set to user-defined conditions For additional information, updated documentation, and a list of accessories, refer to Banner Engineering's website, www.bannerengineering.com/wireless WARNING: •...
  • Page 2: Configure The Dip Switches

    ® Sure Cross Performance P15E Node CAUTION: Electrostatic Discharge (ESD) ESD Sensitive Device. This product uses semiconductors that can be damaged by electrostatic discharge (ESD). When performing maintenance, care must be taken so the device is not damaged. Disconnect power from the device when accessing the internal DIP switches.
  • Page 3: Dip Switch Settings

    ® Sure Cross Performance P15E Node 4. Remove the black cover plate from the bottom of the device's cover. The DIP switches are located behind the rotary dials. After making the necessary changes to the DIP switches, place the black cover plate back into position and gently push into place.
  • Page 4 ® Sure Cross Performance P15E Node ® Wiring Your Sure Cross Device Use the following wiring diagrams to first wire the sensors and then apply power to the Sure Cross devices. Wiring for Power and I/O 24V. 24 V courtesy power output AI1.
  • Page 5 ® Sure Cross Performance P15E Node Wiring Diagrams for AC Power Power Only Switched AC Relays Power and Switched AC Relays 100-277 V ac Normally Closed 100-277 V ac AC Neutral AC Line AC Neutral Relay 1 AC Earth Normally Open AC Earth Normally Closed AC Line...
  • Page 6: Holding Registers

    For DXM Controllers with an internal DX80 radio, connect a computer to the DXM Controller using a USB or Ethernet connection. Download the most recent revisions www.bannerengineering.com/ of the UCT software from Banner Engineering's website: wireless The USB to RS-485 adapter cable is not required for the DXM Controller. For standalone DX80 Gateway devices use: •...
  • Page 7 ® Sure Cross Performance P15E Node Specifications Performance Radio Specifications Radio Range 900 MHz Compliance (1 Watt) 900 MHz, 1 Watt: Up to 9.6 km (6 miles) FCC ID UE3RM1809: This device complies with FCC Part 15, Subpart C, 15.247 2.4 GHz, 65 mW: Up to 3.2 km (2 miles) IC: 7044A-RM1809 Antenna Minimum Separation Distance...
  • Page 8 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

This manual is also suitable for:

Dx80n9x7s-p15eDx80n2x7s-p15e