conductors, circuit breakers, and/or fuses must be sized in accordance to the
input ratings shown below:
220-240 V AC, 50 Hz:
• Permanently connected
• Rated 220-240V AC – 50 Hz
• One and two pump spas are rated 16A for low amp setting (heater off
during high-speed) and 32A for high amp setting (heater on during high-
speed).
Improperly wired spas can cause irreversible damage resulting in blown fuse
and melted terminal block, and to other electrical components. Also, damage
caused to components or equipment caused by high or low voltage, brown outs
or electric surges is not covered under warranty.
Electrical Service Connections at Terminal Block, Inside Spa Controller:
The spa must be supplied through a single MCB with a certified residual current
device (RCD) with a rated current trip not exceeding 30 mA. Means for spa
disconnection from supply must be incorporated in the fixed wiring.
Recommended supply conductor nominal cross sectional area is 4mm2 for 16A
rating, 6 mm2 for 32A rating.
NOTE: If the power cord on any piece of electrical equipment, such as a jet
pump or ozone generator, becomes damaged, do not use the spa until the cord
has been repaired. Consult your authorized Marquis Spas® dealer for
assistance on such repair.
Electrical Diagram: Envy, Envy II, Euphoria, Mirage, Promise, Quest,
Rendezvous, Resort, Retreat, Reward and Spirit
®
M A R Q U I S
S P A S
Electrical Diagram: Destiny and Epic
Improperly wired spas are beyond Marquis Corp. control and are not covered
under the warranty. Other items beyond Marquis Corp. control include, but are
not limited to, damage resulting from: improper connections; accidents; failure to
follow procedures and instructions defined in the Marquis Spas® printed
instructions; cleaning agents; and natural occurrences including but not limited
to rodent or insect infestation, mold, lightning and other acts of nature.
O W N E R ' S
M A N U A L
4

Advertisement

Table of Contents
loading

Table of Contents