Carrier 80AWX Series Installation Manual page 22

Control module
Table of Contents

Advertisement

Controller operation
Code
Level
Variable Name
Nr.
CURRENT WSP FOR
153 Inst.
ZONES
154 Inst.
RUNTIME
155 Inst.
RESET
156 Inst.
CDU CAPACITY
NUI SW VERSION
157 Inst.
AND RELEASE
GMC SW VERSION
158 Inst.
AND RELEASE
Note:
- cycle power after modifying Installer parameters
- take special care in setting System setup parameters
- parameters referring to system with 2 zone kit are written in gray.
80AWX- 80AWH
22
DESCRIPTION
Current water setpoint defined by the system control for the
different zones
Use Days button for Reading the below.
0. Water setpoint for Zone 1
1. Water setpoint for Zone 2
2. Current water setpoint
Use Days button to read below values. Real values are read
values multiplied by 10.
0. Compressor run time (hours)
1. Water pump Run time (hours)
2. Backup heater 1 run time (hours)
3. Backup heater 2 run time (hours)
Use Days button to select the following
0. Compressor run time Reset
0: No Reset
1: Reset
1. Water pump run time reset
0: No Reset
1: Reset
2. Backup heater 1 run time
0: No Reset
1: Reset
3. Backup heater 2 run time
0: No Reset
1: Reset
Software & Matching
Outdoor unit capacity
User interface Software Version
System control Software Version & Release
VALUE RANGE
DEFAULT
Min
Max
-
-
-
-
-
-
0
1
0
-
-
-