Replacement Parts, Service Handbooks And Training Aids; Sequence Of Operation Flow Chart - State Water Heaters SBN85390NE/A Installation Operation & Maintenance

108 series commercial gas, glass-lined, tank-type water heater
Hide thumbs Also See for SBN85390NE/A:
Table of Contents

Advertisement

REPLACEMENT PARTS, SERVICE HANDBOOKS AND TRAINING AIDS

Replacement parts may be ordered through State dealers, authorized servicers or distributors. Refer to the Yellow Pages for where
to call or contact the State Water Heaters, 500 Lindahl Parkway, Ashland City, TN 37015. When ordering parts be sure to state the
quantity, part number and description of the item(s) including the complete model and serial number as it appears on the product.
Refer to the parts list for more information.
Description of this flow chart can be found in the "SEQUENCE OF OPERATION" section found on page 23.
Switch power on
to unit.
Thermostat calls
for heat.
Ignition Control
Board performs
diagnostic check on
components
Ignition Control
Board sends power
to Exhaust Inducer
Exhaust Inducer
engages Prover
Switch
Ignition Control
Board provides
power to Silcon
Nitride Ignitor
Silicon Nitride
Ignitor
warms up for
20 seconds

SEQUENCE OF OPERATION FLOW CHART

Ignition
Control Board
opens Gas
Valve.
Ignition Control
Board shuts off
Silicon Nitride
Ignitor after
3 seconds
Ignition Control
Board waits 3 more
seconds to
monitor Flame
Sensor.
Did Main
Burner Light?
Ignition Control
Board monitors
units until T'Stat
is satisfied.
NO
YES
30
Ignition Control
Board shuts off Gas
Valve and allows the
Exhaust Inducer to
purge appliance for
20 seconds.