ROUGH-IN-DIMENSIONS -------------------------------- 2
FOREWORD ------------------------------------------------- 3
GENERAL SAFETY INFORMATION -------------------- 4
Precautions --------------------------------------------------- 4
Grounding Instructions ------------------------------------ 4
Chemical Vapor Corrosion ------------------------------- 4
Improper Combustion ------------------------------------- 4
Extended non-use Periods ------------------------------- 4
Insulation Blankets ----------------------------------------- 4
High Altitude Installation ---------------------------------- 5
FEATURES ---------------------------------------------------- 5
Self-Cleaning Hydro Cannon ---------------------------- 5
High Limit Switch ------------------------------------------- 5
Electronic Ignition Control -------------------------------- 5-6
Exhaust Inducer (Blower Assy.) ------------------------- 6
Circulating Pump ------------------------------------------- 6
Dishwashing Machine Requirement ------------------ 6
INSTALLATION INSTRUCTIONS ------------------------ 6
Required Ability ---------------------------------------------- 6
Uncrating ------------------------------------------------------ 6
Locating The Heater --------------------------------------- 6-7
Levelling ------------------------------------------------------- 7
Clearances --------------------------------------------------- 7
Hard Water ---------------------------------------------------- 8
Air Requirements ------------------------------------------- 8
Venting --------------------------------------------------------- 8
Technical Data Venting ------------------------------------ 9-10
Multiple Heater Manifold ---------------------------------- 11
Water Line Connections ---------------------------------- 11
Thermometers (Not Supplied) -------------------------- 11
Relief Valve --------------------------------------------------- 11
INLET/OUTLET USAGE ----------------------------------- 12
General -------------------------------------------------------- 12
Code Restrictions ------------------------------------------ 12
INSTALLATION DIAGRAMS ------------------------------- 13-18
MANIFOLD KITS --------------------------------------------- 19
Heater Wiring ------------------------------------------------ 20

FOREWORD

These designs comply with ANSI Z21.10.3 as an automatic
circulating or automatic storage tank type water heater.
Heaters having an input of 310,000, 366,000, 390,000 Btuh with
a recovery rating of 277.3 gph or more also comply with ANSI
Z21.10.3 as an automatic instantaneous type heater.
Detailed installation diagrams are found in this manual. These
diagrams will serve to provide the installer with a reference for
the materials and methods of piping necessary. It is highly
essential that all water, gas piping and wiring be installed as
shown on the diagrams.
Particular attention should be given to the installation of
thermometers at the locations indicated on the diagrams as
these are necessary for checking the proper functioning of the
heater.
The heater is designed to operate on natural gas only. If you
have obtained this heater for use on propane-STOP. Do not
Page
Gas Piping ---------------------------------------------------- 21
Purging -------------------------------------------------------- 21
Gas Pressure Regulator ---------------------------------- 21-22
OPERATION -------------------------------------------------- 22
General -------------------------------------------------------- 22
Filling ----------------------------------------------------------- 22
SEQUENCE OF OPERATION ---------------------------- 23
Lighting and Operation ------------------------------------ 24
Water Temperature Control ------------------------------ 25
Checking Venting ------------------------------------------- 25
PREVENTIVE MAINTENANCE --------------------------- 25
Check The Ignitor Assembly ----------------------------- 25
Ignitor Assembly -------------------------------------------- 25-26
Main Burner --------------------------------------------------- 26
Gas Valves ---------------------------------------------------- 26
Checking The Input ----------------------------------------- 26
Venting System ---------------------------------------------- 27
Relief Valve --------------------------------------------------- 27
Hot Water Odor ---------------------------------------------- 27
Anode Rod Inspection ------------------------------------- 27
Flushing ------------------------------------------------------- 27
Draining ------------------------------------------------------- 27
Commercial Water Heaters ------------------------------ 28
Deliming Solvents ------------------------------------------ 28
Tank Cleanout Procedures ------------------------------- 28-29
Ignition Module System ----------------------------------- 29
System Diagnostics ---------------------------------------- 29
SERVICE ------------------------------------------------------ 29
Electrical Servicing ----------------------------------------- 29
and Training Aids ------------------------------------------- 30
Sequence of Operation Flow Chart -------------------- 30
Operational Checklist -------------------------------------- 31
Limited Warranty -------------------------------------------- Insert
install this water heater. Immediately call your supplier to correct
the situation.
These heaters may be installed on combustible floors.
In addition to these instructions, the equipment shall be installed
in accordance with those installation regulations in force in the
local area where the installation is to be made. These shall be
carefully followed in all cases. Authorities having jurisdiction
should be consulted before installations are made.
The installation must conform to these instructions and the local
code authority having jurisdiction. In the absence of local codes,
the installation must comply with the latest editions of the
National Fuel Gas Code, ANSI Z223.1/NFPA 54 and the National
Electrical Code, NFPA 70, documents are available from the
National Fire Protection Association, 1 Batterymarch Park, Quincy,
MA 02269.