Paper Unparking; Test Printing; Short Self Test - Star Micronics lC-10 User Manual

Star micronics colour printer users manual
Hide thumbs Also See for lC-10:
Table of Contents

Advertisement

3.
Tear off the printed
form at the last perforation,
leaving not more than
about half a page showing
above the top cover.
If necessary,
press the
Paper Feed switch to feed paper forward
until a perforation
is located
just above the top cover, and tear there.
4.
Press the Print Pitch switch on the control
panel and hold it down.
5.
Still holding
the Print Pitch switch down, press the Paper Feed switch.
The printer
will automatically
feed the fanfold
form backward
until the
paper is completely
free of the platen.
6.
Move the release lever to the down position.
7.
Mount
the paper guide in the upright
position.
Now you can load single sheets either semiautomatically
or manually,
as explained
previously.
The fanfold
paper remains
parked
at the back of
the printer.
When
you want
to resume
using
fanfold
paper,
the procedure
is as
follows.
Paper unparking
1.
Remove
all single sheets from the printer
and close the paper bail.
2.
Mount
the paper guide in the horizontal
position.
3.
Move the release lever to the up position.
4.
With power ON, move the bail lever forward.
The printer
will auto-
matically
feed the parked
fanfold
paper into position
for printing.
5.
Move the bail lever back to close the bail.
Now you are ready to print.
TEST PRINTING
After loading
paper, you can test the printer
as described
next.
Short self test
This procedure
prints a seven-line
"barber-pole"
test pattern,
each line
in a different
colour.
The lines are eight inches wide, so the paper should
be at least that wide.
-
1.
Check that paper is in position
for printing.
2.
With power off, press the On Line switch on the control
panel and hold
it down.
3.
Still holding
the On Line switch down, turn the printer's
power on.
The printer
will automatically
start printing
its short test pattern.
You
can release the On Line switch after printing
starts.
To remove
the paper
at the end of the test, switch power OFF, then turn the platen knob. (Don't
turn the platen
knob while power is on.)
12
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents