4.7 Steam Vent Components

It may be necessary to have to clean or replace the steam vent components.
Also provided are instructions for adding additional vent piping to the exterior of
the unit to enable the safe venting of steam.
INTERIOR STEAM VENT - SN 58694 AND
BELOW
1. Shut off external breaker to the unit.
2. Remove the Left-Side Panel by removing
the Sheet Metal Screws holding it in
place.
3. Detach the 1/4 inch silicon hose from
the 90° elbow by removing the hose
clamp.
4. Remove the 90° elbow from the
bullhead T-fitting.
5. Use compressed air to blow out both the
90° elbow and the T-fitting.
6. A brass bore brush can be used to clean
the fittings also.
7. Reinstall in reverse order.
INTERIOR STEAM VENT - SN 58695 AND
ABOVE
1. Shut off external breaker to the unit.
2. Remove the Left-Side Panel by removing
the Sheet Metal Screws holding it in
place.
3. Detach the 1/2 inch silicon hose from
the bottom of the brass vent assembly by
removing the hose clamp.
4. Use compressed air to blow out the vent
assembly.
5. A brass bore brush can be used to clean
the fittings also.
6. Reinstall in reverse order.
SP8026-1909
EVOLUTION ELECTRIC STEAMER
FIG 4.7A
48